Occlusion of the common and internal iliac arteries for aortoiliac aneurysm repair: experience with the Amplatzer vascular plug.

نویسندگان

  • S Marlene Grenon
  • Joel Gagnon
  • York Hsiang
  • Ravi Sidhu
  • David Taylor
  • Jason Clement
  • Jerry Chen
چکیده

BACKGROUND We sought to evaluate and describe our centre's experience with the Amplatzer vascular plug (AVP) for the occlusion of common and internal iliac arteries (CIA; IIA) during endovascular aortic aneurysm repair (EVAR). METHODS We performed a retrospective analysis of 20 consecutive patients between October 2006 and December 2007, who underwent occlusion of the CIA or IIA before or during EVAR to prevent endoleak. RESULTS Among these 20 patients, 21 occlusion procedures occurred and 20 were successful. In the only unsuccessful case, the patient had EVAR, but occlusion with an AVP was not possible because of severe narrowing at the origin of the vessel. Of the successfully treated patients, 2 presented with ruptured aneurysms, whereas the others had elective procedures. Eleven patients received aortouni-iliac grafts and femoral-femoral bypass, and 9 patients received a bifurcated stent graft. In 5 patients, the AVP occlusion and EVAR procedures were staged; in these cases occlusion occurred first, followed by EVAR on average 29 (standard deviation [SD] 23) days later. We deployed 7 AVPs in the CIA, whereas 13 were deployed in the IIA. The average diameter of the vessels occluded was 10 (SD 1) mm and the average size of the device used was 13 (SD 1) mm, representing a device diameter 28% (SD 2%) greater than the vessel diameter. We used a single device in 18 patients, whereas 2 devices were deployed in the same artery in 2 patients. Four patients underwent concomitant coil embolization. On follow-up computed tomography (CT) scans, all occlusion procedures were clinically successful. At the 14-month (SD 1 mo) follow-up, 4 patients had a small type-II endoleak unrelated to the occlusion procedure and 1 had a type-I endoleak that required graft limb extension. Four patients had buttock claudication but none had changes in sexual function, ischemic complications or device dislodgement on CT scans. CONCLUSION The AVP is a safe and effective method to occlude the CIA and IIA in patients undergoing EVAR.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peripheral vascular applications of the Amplatzer vascular plug.

PURPOSE To present our experience using the Amplatzer vascular plug in various arterial and venous systems, and follow-up results. MATERIALS AND METHODS Between May 2005 and October 2006, 20 Amplatzer vascular plugs were used to achieve occlusion in 20 vessels in 12 patients (10 male, 2 female) aged between 24 and 80 years (mean age, 55 years). Localization and indications for embolotherapy w...

متن کامل

Internal iliac artery embolization before endovascular repair of aortoiliac aneurysms with a nitinol vascular occlusion plug.

PURPOSE To evaluate the acute and midterm effectiveness of a novel vascular occlusion device for embolization of the internal iliac artery (IIA) before endovascular repair of aortoiliac aneurysms. MATERIALS AND METHODS Between March 2005 and April 2006, nine men (mean age, 75 years +/- 5; range, 66-83 y) with aortoiliac aneurysms underwent bifurcated endovascular stent-graft procedures. All t...

متن کامل

Applications of the Amplatzer Vascular Plug to various vascular lesions.

The Amplatzer® Vascular Plug (AVP) can be used to embolize medium-to-large high-flow vessels in various locations. Between 2009 and 2012, 41 AVPs (device size, 6-22 mm in diameter) were used to achieve occlusion in 31 patients (24 males, seven females) aged 9-92 years (mean age, 54.5 years). The locations and indications for embolotherapy were as follows: internal iliac artery embolization befo...

متن کامل

EVAR of aortoiliac aneurysms with branched stent-grafts.

INTRODUCTION Branched iliac stent-grafts (bSG) have recently been developed in order to preserve internal iliac artery (IIA) flow in patients with aneurysmal or short common iliac arteries. The aim of this study is to evaluate a single-center experience with bSG for the IIA. METHODS Twenty-two male patients (70 (IQR 65-79) years old) underwent EVAR with 23 bSG (1 bilateral repair) between Sep...

متن کامل

Internal iliac artery pseudo aneurysm occlusion using amplatzer vascular plug.

Pseudoaneurysm of the internal iliac artery is a rare occurrence. Our patient presented with pain over the lower abdomen which also radiated to the back. An Angiogram of the aorta and the iliac arteries showed a pseudoaneurysm of the right internal iliac artery which measured about 8 x 8 cm with a proximal branch of the internal iliac artery distended. Initial efforts of trying to embolize the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of surgery. Journal canadien de chirurgie

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2009