Simple, rapid determination of serum guanase activity with the Hitachi 736 automated discrete analyzer.

نویسندگان

  • Y Nishikawa
  • K Fukumoto
  • F Watanabe
چکیده

In this new method for determining serum guanase activity by use of the Hitachi 736-40 automated analyzer, serum is incubated with a mixture of xanthine oxidase, superoxide dismutase, and catalase; a reagent containing KCN, guanine, nitrotetrazolium blue, and Triton X-100 is added; and the increase in absorbance at 570 and 660 nm is measured for 2.4 min. Only 20 microL of sample is required, and results are linearly related to the activity concentration of guanase up to 30 U/L. Within-run and day-to-day precision (CV) was respectively 2.6 to 4.2% and 3.5 to 5.5% over 0-30 U of guanase activity per liter. The normal reference interval, as calculated from data on 40 healthy persons, is 0.1 to 2.2 U/L. Results correlate well (r = 0.997) with those by a kinetic method (Clin Chem 27: 560, 1981). The guanase activity of 150 samples can be measured within 1 h by this method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinetic measurement of guanine deaminase in serum with a centrifugal analyzer.

We describe an enzymic, one-step kinetic method for determination of guanine deaminase (guanase, EC 3.5.4.3) in serum with a centrifugal analyzer. A combined enzyme-substrate system consists of the enzymes xanthine oxidase, catalase, and aldehyde dehydrogenase, the coenzyme NAD+, the substrate guanine, and ethanol in tris(hydroxymethyl)methylamine buffer, with KCl added as activator for aldehyd...

متن کامل

Colorimetric determination of serum guanase activity.

A colorimetric method for the determination of serum guanase has been developed whereby ammonia, formed by the deamination of guanine, is measured by the phenatehypochlorite reaction. Variations in substrate concentration, time of incubation, pH, temperature, and concentration of enzyme have been investigated with respect to enzyme activity. The determination of serum guanase appears to be usef...

متن کامل

A simple and sensitive radiochemical assay for plasma guanase.

A simple and sensitive radiochemical micro-assay has been developed for the determination of plasma guanase activity. The method is based upon the measurement of the conversion of 14C-labeled guanine to xanthine, catalysed by the enzyme guanase (guanine aminohydrolase;EC 3.5.4.3). Using this method, the catalytic activity in the plasma of adult healthy controls was 0.040 +/- 0.09 nmol/h.mg prot...

متن کامل

Rapid kinetic rate assay of the serum alpha-L-fucosidase in patients with hepatocellular carcinoma by using a novel substrate.

BACKGROUND Developing kinetic rate assay kit for alpha-L-fucosidase (AFU) by using a novel substrate 2-chloro-4-nitrophenyl-alpha-L-fucopyranoside (CNPF) and clinical implication in the diagnosis of hepatocellular carcinoma (HCC). METHODS We have evaluated the new kinetic rate assay kit using a novel substrate for serum AFU employing Hitachi 7170 automated analyzer. The reaction was carried o...

متن کامل

Rapid automated determination of adenosine deaminase and lysozyme for differentiating tuberculous and nontuberculous pleural effusions.

The catalytic concentration of pleural adenosine deaminase (ADA) and the ratio of pleural lysozyme (PL) to serum lysozyme (SL) were measured in consecutive patients (49 tuberculous and 179 nontuberculous) with two automated procedures in a Hitachi 717 analyzer. Using sensitivity and specificity curves, we established cutoff values at 33 U/L for ADA and 1.7 for the PL/SL ratio. The sensitivity o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 1985