Finite Element Analysis of a Contactless Transformer
نویسندگان
چکیده
Inductively coupling power transfer is an emerging technique, which enables power transfer to loads through air. The contactless transformer is the key component of it, and the design of a transformer is a timeconsuming work with a large number of tests. In this paper, a design method of contactless transformer with finite element analysis is presented. First the contactless transformer model is deduced from Maxwell Equations, and the self inductance and mutual inductance computational equations are given as well. Then the magnetic field distributions of contactless transformer with different air gaps are presented by simulation of MAXWELL ANSOFT. Furthermore, the skin and proximity effects are analyzed as well. At last, the results are compared with the experimental results with the same dimension and material. The analyses show that there has a good agreement with each other. So by this method, the design period of a contactless transformer will be shorter than before.
منابع مشابه
Power Auto-transformer Mechanical Faults Diagnosis Using Finite Element based FRA
Frequency response analysis (FRA) is a sensitive method established for testing the mechanical integrity of transformers. However, interpretation of FRA signature still needs expert opinions and there is no FRA interpretation code generally accepted. Various mechanical faults with different extents on power transformers are required to aid FRA interpretation. To address this challenge, in...
متن کاملDiscrimination of Inrush from Fault Currents in Power Transformers Based on Equivalent Instantaneous Inductance Technique Coupled with Finite Element Method
The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equiv...
متن کاملRecognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces
Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...
متن کاملDesign and analysis of contactless transformer using series resonant converter
A loosely contactless transformer with a large air gap has small magnetizing inductance and large leakage inductance comparing with a closely conventional transformer. This paper focus on analysis, design and measurement results of the loosely winding contactless transformer using resonant converter. Finally, the experimental set up is built to transfer power of 300 W over the different gap var...
متن کاملMethodology for Repeated Load Analysis of Composite Structures with Embedded Magnetic Microwires
K. Semrád, K. Draganová, Faculty of Aeronautics, Technical University of Kosice, Slovakia The article processes issue of strength of cyclically loaded composite structures with the possibility of contactless stress measuring inside a material. For this purpose a contactless tensile stress sensor using improved induction principle based on the magnetic microwires embedded in the composite struct...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JNW
دوره 8 شماره
صفحات -
تاریخ انتشار 2013