Interference of blood cell lysis on routine coagulation testing.

نویسندگان

  • Giuseppe Lippi
  • Martina Montagnana
  • Gian Luca Salvagno
  • Gian Cesare Guidi
چکیده

CONTEXT Preanalytical factors influencing the reliability of laboratory testing are commonplace. It is traditionally accepted that hemolytic samples are unsuitable for coagulation assays because of the release of hemoglobin, intracellular components, and thromboplastic substances from damaged blood cells. OBJECTIVE To evaluate the influence of blood cell lysis on routine coagulation testing. DESIGN Twelve aliquots prepared by serial dilutions of homologous lysated samples collected from 10 different subjects, and displaying a final percentage of lysis ranging from 0% to 9.1%, were tested for prothrombin time, activated partial thromboplastin time, fibrinogen, and dimerized plasmin fragment D. Lysis was achieved by subjecting citrated whole blood to a freeze-thaw cycle. OUTCOME MEASURES Interference from blood cell lysis on routine coagulation testing. RESULTS Statistically significant increases in prothrombin time and dimerized plasmin fragment D were observed in samples containing final lysate concentrations of 0.5% and 2.7% respectively, whereas significant decreases were observed in activated partial thromboplastin time and fibrinogen in samples containing a final lysate concentration of 0.9%. The current analytical quality specifications for desirable bias are +/-2.0% for prothrombin time, +/-2.3% for activated partial thromboplastin time, and +/-4.8% for fibrinogen. Percent variations from the baseline values exceeding the current analytical quality specifications for desirable bias were achieved for lysate concentrations of 0.9% (prothrombin time and activated partial thromboplastin time) and 1.8% (fibrinogen), corresponding to average free plasma hemoglobin concentrations of 1.7 and 3.4 g/L, respectively. CONCLUSION Our results confirm that, although slightly hemolyzed specimens might still be analyzable, a moderate blood cell lysis, as low as 0.9%, influences the reliability of routine coagulation testing. Because the interference in coagulation assays has a wide interindividual bias, we do not recommend lysis correction and we suggest that the most appropriate corrective measure should be free hemoglobin quantification and sample recollection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی تاثیر عناصر مس، روی و آلومینیوم بر شاخص‌های انعقاد و فیبرینولیز

Introduction: Myocardial infarction as a leading cause of death in most populations is associated with blood clot formation in coronary artery, and rapid clot lysis is important for patient treatment. Some reports have indicated the effects of some trace elements on blood coagulation and clot lysis. The aim of this study was to evaluate the effects of zinc, copper and aluminum on in-vitro coagu...

متن کامل

Evaluation of the Interference of the Microwave Radiation Emitted from GSM Mobile Phones on the Performance of Cell Counters

Abstract Background and Objectives: Incidents related to electromagnetic interference with medical devices have been reported over the past decades. It has also been indicated that the microwave radiation emitted from mobile phones interferes with the operation of medical devices therefore, this study aimed at testing the interference by GSM mobile phones with cell counters. Material and Method...

متن کامل

Influence of hemolysis on routine clinical chemistry testing.

BACKGROUND Preanalytical factors are the main source of variation in clinical chemistry testing and among the major determinants of preanalytical variability, sample hemolysis can exert a strong influence on result reliability. Hemolytic samples are a rather common and unfavorable occurrence in laboratory practice, as they are often considered unsuitable for routine testing due to biological an...

متن کامل

Does routine repeat testing of critical laboratory values improve their accuracy?

  Background: Routine repeat testing of critical laboratory values is very common these days to increase their accuracy and to avoid reporting false or infeasible results. We figure that repeat testing of critical laboratory values has any benefits or not.   Methods : We examined 2233 repeated critical laboratory values in 13 different hematology and chemistry tests including: hemoglobin, white...

متن کامل

An in vitro Comparative study upon the Hemolytic, Thrombogenic, Coagulation parameters and Stability properties of the Hemiscorpiuslepturus Venom

Hemiscorpius lepturus belonging to Hemiscorpiidae family is the most venomous of all types of scorpion existing in south west of Iran causing hemoglobinuria and dermal lesions by envenomation. We compare the hemolytic pattern upon time in different domestic animals upon time according to their different sphingomyelin contents. In addition other in vitro hematologic parameters, platelet lysis, c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of pathology & laboratory medicine

دوره 130 2  شماره 

صفحات  -

تاریخ انتشار 2006