Validation of Noise Figure Measurements by Means of MR Imaging
نویسندگان
چکیده
Introduction In order to maximize the signal-to-noise-ratio (SNR) performance of an MR receiver coil the preamplifier used should add as little noise as possible. The amount of added noise is characterized by its noise figure (NF). Standard NF measurement of a preamplifier requires a tuner to present reference noise at varying complex impedance to the input of the device. Such tuners are not commonly available at MR frequencies but it has recently been shown that they can be reliably replaced by suitable lumped-element circuits between the noise source and the preamplifier [1]. The aim of the present work project was to cross-validate this method of NF measurement by SNR measurements in actual MR data obtained with a commercial imaging system. Materials and Methods In order to calculate the expected NF of a preamplifier at any given source impedance its so-called noise parameters Fmin, Rn, Gopt and Bopt [2] have to be known. The relationship of the noise parameters and the noise factor is given by Eq. (1), which can be used to extract noise parameters from NF measurements by fitting [3,4]. In a cascade of active devices the contribution of each device to the overall noise factor Ftot is given by Eq. (2), which is known as Friis’ formula where Fi are the individual noise factors of the different devices and Gi are the corresponding available gains. Looking at an assembled receiver coil the coil element, the matching network, and the preamplifier can be regarded as the different stages. Their noise factors must be determined individually before the overall noise factor can be calculated. As long as the available gain of the preamplifier is large (> 20 dB) the contributions of the rest of the receiver chain can be neglected. Since the coil element and the matching network usually do not contain any active devices their available gain can be assumed to be 1. The noise factor Fc of the coil element can be calculated from Eq. (3), where SNR1 and SNR2 are taken at the input and output of the coil element, respectively, Gc, Nc and Rc denote the gain, noise power, and equivalent series resistance of the coil element, and Ns and Rs are the noise power and equivalent series resistance of the sample. For a given measurement setup, Rc and Rs can be readily calculated from unloaded and loaded Q-factor measurements of the coil element. Similarly the noise factor Fm of the matching network can be calculated from a Q-factor measurement. The noise factor Fpreamp of the preamplifier can then be calculated from Eq. (1) if the source impedance seen by the preamplifier is additionally measured. In total Eq. (1) can be rewritten in the form of Eq. (4). Since the signal level at the very input of the receive chain is not known, ratios of total noise factors and SNR values of two measurements must be calculated according to Eq. (5). MR measurements were performed on a 3T Philips Achieva system (Philips Healthcare, Best, The Netherlands) using a 2D gradient echo sequence. The flip angle was set to the Ernst angle, which was determined empirically. The measurement setup is shown in Fig. 1, including a homogeneous phantom filled with copper sulfate solution. A proprietary preamplifier with a minimal noise figure of 0.6 dB was used. Its matching to the preamplifier was varied in a way similar to that described in Ref. [5]. For each matching configuration image as well as noise data were acquired and the source impedance seen by the preamplifier was measured using an Agilent E5071 C network analyzer. SNR maps were calculated from the image and noise data as described in Ref. [5], taking the square of the resulting values to obtain SNR in terms of power as underlying Eqs. (3,5). Overall SNR values with high statistical power were then determined by averaging over the whole phantom. Results and Discussion Table 1 shows the results of this study, juxtaposing total noise factors and SNR values as well as their ratios between different matching configurations. Notably, the noise factor and SNR ratios agree to within 5%, indicating the validity of both the bench method for NF measurement and the noise analysis of the receive chain described above. This agreement offers the important confirmation that optimizing the NF on the bench actually translates into quantitatively corresponding SNR benefits in MR experiments. To the best of our knowledge such cross-validation has not previously been reported. References [1] Massner et al., Proc. ISMRM, p. 328 (2007) [2] “IRE Standards on methods of measuring the noise in linear two-ports”, Proc. IRE 48,p.60 (1960) [3] Lane et al., Proc. of the IEEE, p. 1461 (1969) [4] Caruso et al., IEEE Trans. Microwave Theory and Techniques 26(9) p. 639 (1978) [5] Nordmeyer-Massner et al., MRM, DOI 10.1002/mrm.21868 (2008) Fig. 1: Measurement setup with coil, preamplifier board and phantom. Preamp Board
منابع مشابه
Analysis and design of a CMOS current reused cascaded distributed amplifier with optimum noise performance
In this paper, analysis, simulation and design of a distributed amplifier (DA) with 0.13µm CMOS technology in the frequency range of 3-40 GHz is presented. Gain cell is a current reused circuit which is optimum in gain, noise figure, bandwidth and also power dissipation. To improve the noise performance in the frequency range of interest, a T-matching low pass filter LC network which is utilize...
متن کاملA Bayesian approach for image denoising in MRI
Magnetic Resonance Imaging (MRI) is a notable medical imaging technique that is based on Nuclear Magnetic Resonance (NMR). MRI is a safe imaging method with high contrast between soft tissues, which made it the most popular imaging technique in clinical applications. MR Imagechr('39')s visual quality plays a vital role in medical diagnostics that can be severely corrupted by existing noise duri...
متن کاملA Broadband Low Power CMOS LNA for 3.1–10.6 GHz UWB Receivers
A new approach for designing an ultra wideband (UWB) CMOS low noise amplifier (LNA) is presented. The aim of this design is to achieve a low noise figure, reasonable power gain and low power consumption in 3.1-10.6 GHz. Also, the figure of merit (FOM) is significantly improved at 180nm technology compared to the other state-of-the-art designs. Improved π-network and T-network are used to obt...
متن کاملRegional myocardial function: advances in MR imaging and analysis.
Cardiovascular magnetic resonance (MR) imaging can provide three-dimensional analysis of global and regional cardiac function with great accuracy and reproducibility. Quantitative assessment of regional function with cardiac MR imaging previously was limited by long acquisition times and time-consuming analysis. The use of steady-state free precession cine MR imaging substantially improves asse...
متن کاملAssessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements
Introduction: Image distortion is one of the major problems of magnetic resonance imaging (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is widely known that the most obvious effect of the inhomogenity of the magnetic fields and the nonlinearity of the gradient is the Geometric Distortion of MR tomograms. In this study, the...
متن کامل