Needle echogenicity in ultrasound-guided lumbar spine injections: a cadaveric study.
نویسندگان
چکیده
BACKGROUND Echogenicity of regional anesthesia needles has been tested on different preclinical models; however, previous studies were done in an ideal experimental setting utilizing high-frequency insonation and superficially located targets. Because steep-angle deep injections are typically required for spinal and other chronic pain procedures, and low-frequency transducers are used, further feasibility study is warranted. OBJECTIVES To determine effectiveness of steep-angle deep injections, typically required for spinal and other chronic pain procedures. STUDY DESIGN Experimental laboratory study. SETTING Willed Body Program, University of Washington. METHODS In-plane lumbar spine procedures with 50° and 70° angles were performed on a human cadaver. The images and video clips of a non-echogenic (Quincke-type) and echogenic (SonoPlex, StimuQuick, and EchoStim) needle placements were presented to 3 blinded assessors who rated the needle visibility on a 4-point scale. The data was statistically analyzed to determine the differences in visibility between the needles with and without the digital image enhancement, and to compare the video clips to captured images. RESULTS ANOVA analysis demonstrated that overall SonoPlex was significantly better (P = 0.02) than other needles. SonoPlex maintained its superiority in the subset of facet joint injections (P = 0.02), followed by Quincke-type, then the StimuQuik, and EchoStim needles. In deep procedures, EchoStim was comparable with SonoPlex (P = 0.03), and they both were better than the other 2 needles. The enhanced images received higher rates, with a 0.6 point mean improved rating (P = 0). LIMITATIONS This study is limited by choice of needles, number of experiments performed, and potential postmortem changes of echogenicity. CONCLUSIONS The SonoPlex needle appeared to have better echogenicity in this study. While non-echogenic Quincke-type needle visibility was adequate in superficial placements, it was limited in deep injections. An imaging enhancement is effective in improving needle visibility and should be used whenever possible.
منابع مشابه
Gelatin-agar lumbosacral spine phantom: a simple model for learning the basic skills required to perform real-time sonographically guided central neuraxial blocks.
This report describes the preparation of a gelatin-agar spine phantom that was used for spinal sonography and to practice the hand-eye coordination skills required to perform sonographically guided central neuraxial blocks. The phantom was prepared by embedding a lumbosacral spine model into a mixture of gelatin and agar in a plastic box. Cellulose powder and chlorhexidine were also added to th...
متن کاملUltrasound guided versus CT-controlled pararadicular injections in the lumbar spine: a prospective randomized clinical trial.
BACKGROUND AND PURPOSE Injection therapies play a major role in the treatment of lower back pain and are to date performed mainly under CT- or fluoroscopic guidance. We conducted this study to evaluate the accuracy, time savings, radiation doses, and pain relief of US-guided pararadicular injections versus CT-controlled interventions in the lumbar spine in a prospective randomized clinical tria...
متن کاملInnervation and nerve injections of the lumbar spine of the horse: a cadaveric study.
REASONS FOR PERFORMING STUDY The distal limb innervation of the horse has been studied extensively to allow use of local anaesthetic techniques to detect the origin of pain in lameness. However, the innervation of the lumbar spine has so far been poorly described and a more precise description may assist clinicians to localise back pain in the horse. OBJECTIVES To gain better knowledge of the...
متن کاملReal-time sonographic imaging for periradicular injections in the lumbar spine: a sonographic anatomic study of a new technique.
OBJECTIVE We conducted this study to develop a sonographically guided approach to the spinal nerve of the lumbar spine and to assess its feasibility and accuracy by means of computed tomography (CT). METHODS Fifty sonographically guided approaches at 5 levels (L1-S1) were performed on 5 embalmed cadavers, which were positioned prone. The spinal nerves of the lumbar spine were shown under sono...
متن کاملEffective radiation dose reduction in computed tomography-guided spinal injections: a prospective, comparative study with technical considerations
Despite the good general patient acceptance, high patient comfort, safety and precision in the needle placement, exposure to radiation in computed tomography (CT)-guided spinal interventions remains a serious concern, and is often used to argue against its use. The aim of this study was to determine the technical possibilities of reducing the radiation dose in CT-guided epidural and periradicul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pain physician
دوره 16 6 شماره
صفحات -
تاریخ انتشار 2013