An experimental model of vitreous motion induced by eye rotations

نویسندگان

  • Andrea Bonfiglio
  • Alberto Lagazzo
  • Rodolfo Repetto
  • Alessandro Stocchino
چکیده

BACKGROUND During eye rotations the vitreous humour moves with respect to the eye globe. This relative motion has been suggested to possibly have an important role in inducing degradation of the gel structure, which might lead to vitreous liquefaction and/or posterior vitreous detachment. Aim of the present work is to study the characteristics of vitreous motion induced by eye rotations. METHODS We use an experimental setup, consisting of a Perspex model of the vitreous chamber that, for simplicity, is taken to have a spherical shape. The model is filled with an artificial vitreous humour, prepared as a solution of agar powder and hyaluronic acid sodium salt in deionised water, which has viscoelastic mechanical properties similar to those of the real vitreous. The model rotates about an axis passing through the centre of the sphere and velocity measurements are taken on the equatorial plane orthogonal to the axis of rotation, using an optical technique. RESULTS The results show that fluid viscoelasticity has a strong influence on flow characteristics. In particular, at certain frequencies of oscillation of the eye model, fluid motion can be resonantly excited. This means that fluid velocity within the domain can be significantly larger than that of the wall. CONCLUSIONS The frequencies for which resonant excitation occurs are within the range of possible eye rotations frequencies. Therefore, the present results suggest that resonant excitation of vitreous motion is likely to occur in practice. This, in turn, implies that eye rotations produce large stresses on the retina and within the vitreous that may contribute to the disruption of the vitreous gel structure. The present results also have implications for the choice of the ideal properties for vitreous substitute fluids.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental investigation of vitreous humour motion within a human eye model.

We present an experimental study of the vitreous motion induced by saccadic eye movements. A magnified model of the vitreous chamber has been employed, consisting of a spherical cavity carved in a perspex cylindrical container, which is able to rotate with a prescribed time law. Care has been taken to correctly reproduce real saccadic eye movements. The spherical cavity is filled with glycerol ...

متن کامل

Numerical simulation of the fluid dynamics in a 3D spherical model of partially liquefied vitreous due to eye movements under planar interface conditions

Partially liquefied vitreous humor is a common physical and biochemical degenerative change in vitreous body which the liquid component gets separated from collagen fiber network and leads to form a region of liquefaction. The main objective of this research is to investigate how the oscillatory motions influence flow dynamics of partial vitreous liquefaction (PVL). So far computational fluid d...

متن کامل

Traction on the retina induced by saccadic eye movements in the presence of posterior vitreous detachment.

Posterior vitreous detachment is a fairly common condition in elderly people. Tractions exerted by the detached vitreous on the retina may result in retinal tears and detachments. We studied how these tractions can arise from saccadic eye movements. Numerical simulations have been performed on a two-dimensional model of the vitreous chamber within a rigid spherical sclera, subjected to prescrib...

متن کامل

Eye rotation induced dynamics of a Newtonian fluid within the vitreous cavity: the effect of the chamber shape.

The dynamics of the vitreous body induced by eye rotations is studied experimentally. In particular, we consider the case in which the vitreous cavity is filled by a Newtonian fluid, either because the vitreous is liquefied or because it has been replaced, after vitrectomy, by a viscous fluid. We employ a rigid Perspex container which models, in a magnified scale, the vitreous cavity of the hum...

متن کامل

Protective effect of chlorogenic acid in an experimental model of Parkinson’s disease induced by 6-hydroxydopamine in rats

Introdution: Parkinson's disease is the second most common neurodegenerative disease. Considering the antioxidant and neuroprotective properties of chlorogenic acid, the purpose of this study was to evaluate the neuroprotective effect of this substance in an experimental model of Parkinson's disease. Methods: In this experimental study, Wisar male rats (n = 32) were divided into 4 groups: sham...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015