Airway management at floor level: a comparison of tracheal intubation using the Macintosh and Airtraq laryngoscopes.

نویسندگان

  • J L Tong
  • A J Gait
  • M Woollard
  • P G Nightingale
  • M R Sharma
چکیده

Practitioners providing pre-hospital care during civilian practice and on military operations may be required to perform airway management and tracheal intubation at floor level. It has been shown that intubation using the Airtraq laryngoscope is easier to learn than standard Macintosh laryngoscopy. We hypothesised that the Airtraq would be easier to use and have shorter intubation times than Macintosh intubation. Sixty volunteers attending a medical conference with no prior Airtraq experience, who were skilled in pre-hospital Macintosh intubation, were recruited. Each was required to intubate an anatomically correct manikin at floor level using a Macintosh and Airtraq laryngoscope. The Airtraq was found to be superior in ease of use (VAS 30 mm, P < 0.001), had a shorter total intubation time (19.4seconds) and a higher intubation success rate (P = 0.012) than the Macintosh laryngoscope (VAS 50 mm, 20.4 seconds). Rotating the tracheal tube 90 degrees anticlockwise during loading into the guiding channel, made the Airtraq intubation easier (VAS 30 mm, P = 0.001) and faster (19.4 seconds, P < 0.001) than with standard orientation of the tube (VAS 40 mm, 25.3 seconds). Airtraq intubation may prove to be easier than Macintosh intubation, when utilised in the clinical pre-hospital setting, though randomised controlled clinical trials are required to confirm this.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of tracheal intubation using the Airtraq or the Macintosh laryngoscope in routine airway management: A randomised, controlled clinical trial.

The Airtraq laryngoscope is a novel single use tracheal intubation device. We compared the Airtraq with the Macintosh laryngoscope in patients deemed at low risk for difficult intubation in a randomised, controlled clinical trial. Sixty consenting patients presenting for surgery requiring tracheal intubation were randomly allocated to undergo intubation using a Macintosh (n = 30) or Airtraq (n ...

متن کامل

Tracheal intubation of morbidly obese patients: a randomized trial comparing performance of Macintosh and Airtraq laryngoscopes.

BACKGROUND The Airtraq laryngoscope is designed to allow visualization of the glottis without alignment of the oral, pharyngeal, and laryngeal axes. We hypothesized that this new airway device would facilitate tracheal intubation of morbidly obese patients. We compared tracheal intubation performance of standard Macintosh laryngoscope with the Airtraq laryngoscope in morbidly obese patients. ...

متن کامل

Endotracheal intubation in patients with cervical spine immobilization: a comparison of macintosh and airtraq laryngoscopes.

BACKGROUND The Airtraq laryngoscope (Prodol Ltd., Vizcaya, Spain) is a novel single-use tracheal intubation device. The authors compared ease of intubation with the Airtraq and Macintosh laryngoscopes in patients with cervical spine immobilization in a randomized, controlled clinical trial. METHODS Forty consenting patients presenting for surgery requiring tracheal intubation were randomly as...

متن کامل

Comparison of the C-MAC®, Airtraq®, and Macintosh laryngoscopes in patients undergoing tracheal intubation with cervical spine immobilization.

BACKGROUND We aimed at comparing the performance of the C-MAC®, Airtraq®, and Macintosh laryngoscopes when performing tracheal intubation in patients undergoing neck immobilization using manual inline axial cervical spine stabilization. METHODS Ninety consenting patients presenting for surgery requiring tracheal intubation were randomly assigned to undergo intubation using a C-MAC® (n=30), Ai...

متن کامل

Learning curves of the Airtraq and the Macintosh laryngoscopes for tracheal intubation by novice laryngoscopists: a clinical study.

BACKGROUND The curved laryngoscope blade described by Macintosh in 1943 remains the most widely used device to facilitate tracheal intubation. The Airtraq laryngoscope is a new, single-use device for tracheal intubation. Several studies compared the use of Airtraq and Macintosh laryngoscopes in simulated intubation scenarios on manikins. We evaluated learning and performance of tracheal intubat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Royal Army Medical Corps

دوره 154 1  شماره 

صفحات  -

تاریخ انتشار 2008