Catecholamines act via a -adrenergic receptor to maintain fetal heart rate and survival
نویسندگان
چکیده
Portbury, Andrea L., Rashmi Chandra, Marybeth Groelle, Michael K. McMillian, Alana Elias, James R. Herlong, Maribel Rios, Suzanne Roffler-Tarlov, and Dona M. Chikaraishi. Catecholamines act via a -adrenergic receptor to maintain fetal heart rate and survival. Am J Physiol Heart Circ Physiol 284: H2069–H2077, 2003. First published February 6, 2003; 10.1152/ajpheart.00588.2002.— Mice lacking catecholamines die before birth, some with cardiovascular abnormalities. To investigate the role of catecholamines in development, embryonic day 12.5 (E12.5) fetuses were cultured and heart rate monitored. Under optimal oxygenation, wild-type and catecholamine-deficient fetuses had the same initial heart rate (200–220 beats/min), which decreased by 15% in wild-type fetuses during 50 min of culture. During the same culture period, catecholamine-deficient fetuses dropped their heart rate by 35%. Hypoxia reduced heart rate of wild-type fetuses by 35–40% in culture and by 20% in utero, assessed by echocardiography. However, catecholamine-deficient fetuses exhibited greater hypoxia-induced bradycardia, reducing their heart rate by 70– 75% in culture. Isoproterenol, a -adrenergic receptor ( -AR) agonist, reversed this extreme bradycardia, restoring the rate of catecholamine-deficient fetuses to that of nonmutant siblings. Moreover, isoproterenol rescued 100% of catecholamine-deficient pups to birth in a dose-dependent, stereospecific manner when administered in the dam’s drinking water. An -AR agonist was without effect. When wild-type fetuses were cultured with adrenoreceptor antagonists to create pharmacological nulls, blockade of -ARs with 10 M phentolamine or -ARs with 10 M bupranolol alone or in combination did not reduce heart rate under optimal oxygenation. However, when combined with hypoxia, -AR blockade reduced heart rate by 35%. In contrast, the muscarinic blocker atropine and the -AR antagonist phentolamine had no effect. These data suggest that -ARs mediate survival in vivo and regulate heart rate in culture. We hypothesize that norepinephrine, acting through -ARs, maintains fetal heart rate during periods of transient hypoxia that occur throughout gestation, and that catecholamine-deficient fetuses die because they cannot withstand hypoxia-induced bradycardia.
منابع مشابه
Catecholamines act via a beta-adrenergic receptor to maintain fetal heart rate and survival.
Mice lacking catecholamines die before birth, some with cardiovascular abnormalities. To investigate the role of catecholamines in development, embryonic day 12.5 (E12.5) fetuses were cultured and heart rate monitored. Under optimal oxygenation, wild-type and catecholamine-deficient fetuses had the same initial heart rate (200-220 beats/min), which decreased by 15% in wild-type fetuses during 5...
متن کاملArg16/Gly beta2-adrenergic receptor polymorphism alters the cardiac output response to isometric exercise.
Normotensive adults homozygous for glycine (Gly) of the Arg16/Gly beta2-adrenergic-receptor polymorphism have 1) greater forearm beta2-receptor mediated vasodilation and 2) a higher heart rate (HR) response to isometric handgrip than arginine (Arg) homozygotes. To test the hypothesis that the higher HR response in Gly16 subjects serves to maintain the pressor response [increased cardiac output ...
متن کاملβ-Adrenergic Receptor-Stimulated Cardiac Myocyte Apoptosis: Role of β1 Integrins
Increased sympathetic nerve activity to the myocardium is a central feature in patients with heart failure. Accumulation of catecholamines plays an important role in the pathogenesis of heart disease. Acting via β-adrenergic receptors (β-AR), catecholamines (norepinephrine and isoproterenol) increase cardiac myocyte apoptosis in vitro and in vivo. Specifically, β(1)-AR and β(2)-AR coupled to Gα...
متن کاملA PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment
Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant.Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a be...
متن کاملDefective Ryanodine Receptor Interdomain Interactions May Contribute to Intracellular Ca Leak A Novel Therapeutic Target in Heart Failure
Heart failure (HF) is a leading cause of morbidity and mortality, and despite optimal medical treatment, patients with NYHA class III–IV symptoms have a 2-year mortality rate approaching 50%.1,2 About half of the deaths from HF occur suddenly,3,4 and ventricular arrhythmias account for a large percentage of these sudden cardiac deaths (SCDs).1 There is a strong correlation between chronic incre...
متن کامل