Prediction of Electromagnetic Interference to the Switching Operation in Substation
نویسندگان
چکیده
In order to study the electromagnetic compatibility of a power system, authors adopted an effective analysis software and proposed a new prediction method. First, simulated and analyzed the electromagnetic transient when switching the no-load bus in the 500kV substation by the ATP software and proved the simulation results were consistent with the actual results; Second, introduced the Gray prediction theory and used it to predict the next electromagnetic interference of the substation, the result showed its soundness.
منابع مشابه
Mitigation of Transient Overvoltages Generated Due to Switching Operations and Lightning in Gas-insulated Substation (GIS) Without Extra Limiter
Gas-insulated substations (GIS) have different specifications in proportion to air-insulated substations. Transformer failures related to lightning and switching are often reported in the gas insulated substation (GIS). This problem is the voltage magnifications due to reflections of switching and lightning surges at various junctions within the GIS. thereby overvoltages in GIS are more importa...
متن کاملارایه یک مبدل افزاینده ولتاژ رزونانسی بدون استفاده از سوئیچ کمکی و ارزیابی EMI هدایتی آن
In this paper, a new step-upresonant DC-DC converter without an auxiliary switch is introduced. All the switching elements act under zero current switching condition at turn-on and turn-off instants. The proposed converter has a simple auxiliary circuit including an inductor and a capacitor. In addition, the size of the main inductor is considerably reduced because it acts as a resonant inducto...
متن کاملEvaluation of the Interference of the Microwave Radiation Emitted from GSM Mobile Phones on the Performance of Cell Counters
Abstract Background and Objectives: Incidents related to electromagnetic interference with medical devices have been reported over the past decades. It has also been indicated that the microwave radiation emitted from mobile phones interferes with the operation of medical devices therefore, this study aimed at testing the interference by GSM mobile phones with cell counters. Material and Method...
متن کاملSensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation
Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...
متن کاملAnalysis and Simulation of ZVS Methods in Full Bridge Converters and Realization of a 3 KW Prototype
One of the difficulties with PWM switching converters is high switching loss and electromagnetic interference due to switching at non-zero voltage and current, which limits the operating frequency. In order to reduce the converter volume and weight (by increasing the frequency) and reducing switching losses, zero voltage and current switching methods are recommended. In this paper, four main ze...
متن کامل