Walsh function current patterns and data synthesis for electrical impedance tomography
نویسندگان
چکیده
A data collection method which uses Walsh functions as injection current patterns is presented. This method can satisfy two conditions: the optimality of current patterns in every iteration and the single-time data measurement condition. The use of Walsh functions simplifies the design of current sources since only two levels of current (+1 and -1) are required, whereas sinusoidal injection requires a digital-to-analog converter to produce many different values of currents. Compared to diagonal or neighboring type of pulses as injection current patterns, Walsh injection current patterns provide more information about the interior of the subject since Walsh function simulate low and high spatial frequency patterns. Therefore, Walsh function injection uses the simplicity of pulse type injection and yields the better distinguishability or SNR of sinusoidal injection.
منابع مشابه
Frequency-Division Multiplexing for Electrical Impedance Tomography in Biomedical Applications
Electrical impedance tomography (EIT) produces an image of the electrical impedance distribution of tissues in the body, using electrodes that are placed on the periphery of the imaged area. These electrodes inject currents and measure voltages and from these data, the impedance can be computed. Traditional EIT systems usually inject current patterns in a serial manner which means that the impe...
متن کاملElectrical Impedance Tomography (EIT) and Its Medical Applications: A Review
This paper reviews the principles of Electrical Impedance Tomography (EIT), different types of current patterns and reconstruction algorithms to assess its potential in medical imaging. A current injection pattern in EIT has its own current distribution profile within the subject under test. Hence, different current patterns have different sensitivity, spatial resolution and distinguishability....
متن کاملImpedance-Based Out-of-Step Protection of Generator in the Presence of STATCOM
This paper presents a novel impedance-based approach for out-of-step (OOS) protection of a synchronous generator. The most popular and commonly used approaches for detecting OOS conditions are based on the measurement of positive sequence impedance at relay location. However, FACTS devices change the measured impedance value and thus disrupt the performance of impedance-based relay function. In...
متن کاملNumerical Meshless Method in Conjunction with Bayesian Theorem for Electrical Tomography of Concrete
Electric potential measurement technique (tomography) was introduced as a nondestructive method to evaluate concrete properties and durability. In this study, numerical meshless method was developed to solve a differential equation which simulates electric potential distribution for concrete with inclusion in two dimensions. Therefore, concrete samples with iron block inclusion in different loc...
متن کاملModified Impedance-Based OOS Protection Based on On-Line Thévenin Equivalent Estimation
In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on medical imaging
دوره 11 4 شماره
صفحات -
تاریخ انتشار 1992