Diagnostic Accuracy of Inverted and Unprocessed Digitized Periapical Radiographs for Detection of Peri-Implant Defects

نویسندگان

  • Seyed Jalal Pourhashemi
  • Zahra Ghoncheh
  • Mohammad Taghi Kiani
  • Raheleh Emami
  • Mohamad Javad Kharazifard
چکیده

OBJECTIVES This study aimed to compare the diagnostic accuracy of inverted and unprocessed digitized periapical radiographs for detection of peri-implant defects. MATERIALS AND METHODS A total of 30 osteotomy sites were prepared in three groups of control, study group 1 with 0.425 mm defects and study group 2 with 0.725 mm defects using the SIC and Astra Tech drill systems with 4.25mm and 4.85mm diameters. Small and large defects were randomly created in the coronal 8mm of 20 implant sites; implants (3.4mm diameter, 14.5mm length) were then placed. Thirty periapical (PA) radiographs were obtained using Digora imaging system (Soredex Corporation, Helsinki, Finland), size 2 photostimulable storage phosphor (PSP) plate sensors (40.0mm×30.0mm) and Scanora software. Unprocessed images were inverted using Scanora software by applying image inversion and a total of 60 images were obtained and randomly evaluated by four oral and maxillofacial radiologists. Data were analyzed using the t-test. RESULTS Significant differences were observed in absolute and complete sensitivity and specificity of the two imaging modalities for detection of small and large defects (P<0.05). Unprocessed digital images had a higher mean in terms of absolute sensitivity for detection of small defects, complete sensitivity for detection of large peri-implant defects and definite rule out of defects compared with inverted images. CONCLUSION Unprocessed digital images have a higher diagnostic value for detection of small and large peri-implant defects and also for definite rule out of defects compared with inverted images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between Inverted and Unprocessed Digitized Radiographic Imaging in Periodontal Bone Loss Measurements

The advances in digital imaging technology in dentistry have provided an alternative to film-based radiography and have given new options to detect periodontal bone loss. The purpose of this study was to compare inverted and unprocessed digitized radiographic imaging in periodontal bone loss measurements. Thirty-five film-based periapical radiographs of patients suffering from moderate to advan...

متن کامل

Diagnostic Accuracy of Digitized Images Using Different Resolution Settings of Digital Camera in Detection of Proximal Caries

Objective: When none of digital systems and scanners is accessible and it is essential to have digitized images of conventional radiographs, digital cameras can be used. The Aim of this study was to investigate whether digital images obtained by different resolutions of a digital camera are matched to the original radiographs in evaluation of caries. Methods: In this diagnostic accuracy in v...

متن کامل

مقایسه دقت تصاویر رادیوگرافی

Statement of Problem: Computer Sciences, in radiology, like other fields, is of high importance. It should also be noted that the accuracy of the technique and work conditions affects the radiographs information considerably. There for, in order to get more accurate diagnostic information, it seems necessary to investigate different digitized radiographic techniques and to compare them with the...

متن کامل

The comparison of the precision of different dental radiographic methods in mandibular peri-implantary measurements: an in vitro study

PURPOSE The objective of this in vitro study was to investigate and compare the precisions of several radiodiagnostic methods used in dentistry for the measurement of peri-implantary sites. MATERIALS AND METHODS Six dental implants were placed in a human cadaver mandible. Periapical radiographs obtained with the parallel as well as the bisecting angle technique, digital and conventional panor...

متن کامل

State of the art and clinical recommendations in periapical implant lesions. 9th Mozo-Grau Ticare Conference in Quintanilla, Spain

This manuscript summarizes the statements and clinical recommendations in periapical implant lesions, as per the state of the art and expert opinion agreement among the participants in the 9th Mozo-Grau Conference 2016 held in Quintanilla (Valladolid, Spain). The current status of the concept, frequency, etiology, diagnosis, clinical classification, surgical procedure and prognosis are describe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2015