A Study of Automated External Defibrillator with the Help of Monophasic and Biphasic Pulse
نویسنده
چکیده
Ventricular fibrillation (VF) is the primary arrhythmia in majority of patients suffering from sudden cardiac attacks that has been focused on particular rhythm. In earlier stage an electrical defibrillator was utilized to treat the sudden cardiac attack with monophasic pulse. This pulse distributes energy to the patient’s heart in only one direction. Thus the tissues of the body will be affected more. AED is a device which analysis the VF rhythm from the normal rhythm and distributes a shock to the patient heart with sudden cardiac attack. AED is when utilized in biphasic pulse for distributing shock to a patient so the tissues of the body will not be affected like monophasic pulse. The simulation tools used are Keil μ vision, proteus8 (ISIS), Cadence orcad capture 16.3, progisp172, Microsoft visio office 2007, Mentor graphics PADS layout 9.2. AED prototypes are mostly adopted in public places like hospitals, Malls, shops, which avail to restore patient’s normal life.
منابع مشابه
Multicenter comparison of truncated biphasic shocks and standard damped sine wave monophasic shocks for transthoracic ventricular defibrillation. Transthoracic Investigators.
BACKGROUND The most important factor for improving out-of-hospital ventricular fibrillation survival rates is early defibrillation. This can be achieved if small, lightweight, inexpensive automatic external defibrillators are widely disseminated. Because automatic external defibrillator size and cost are directly affected by defibrillation waveform shape and because of the favorable experience ...
متن کاملOptimization of Beam Orientation and Weight in Radiotherapy Treatment Planning using a Genetic Algorithm
Introduction: The selection of suitable beam angles and weights in external-beam radiotherapy is at present generally based upon the experience of the planner. Therefore, automated selection of beam angles and weights in forward-planned radiotherapy will be beneficial. Material and Methods: In this work, an efficient method is presented within the MATLAB environment to investigate how to improv...
متن کاملA prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans.
Biphasic waveforms have been suggested as a superior waveform for ventricular defibrillation. To test this premise, a prospective randomized intraoperative evaluation of defibrillation efficacy of monophasic and biphasic waveform pulses was performed in 22 survivors of out of hospital ventricular fibrillation who were undergoing cardiac surgery for implantation of an automatic defibrillator. Th...
متن کاملComparison of outcomes after use of biphasic or monophasic defibrillators among out-of-hospital cardiac arrest patients: a nationwide population-based observational study.
BACKGROUND The use and popularity of the biphasic waveform defibrillator as a replacement for the monophasic waveform defibrillator are increasing, but it is unclear whether this can improve the rate of survival among out-of-hospital cardiac arrest patients. This study aimed to verify the hypothesis that the outcome of out-of-hospital cardiac arrest patients who received defibrillation shock wi...
متن کاملWaveform analysis of biphasic external defibrillators.
BACKGROUND AND OBJECTIVE All internal defibrillators and some external defibrillators use biphasic waveforms. The study analysed the discharged waveform pulses of two manual and two semi-automated biphasic external defibrillators. METHODS AND RESULTS The defibrillators were discharged into resistive loads of 25, 50 and 100 Omega simulating the patient's transthoracic impedance. The tested bip...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015