Assessment of patient perception of glaucomatous visual field loss and its association with disease severity using Amsler grid
نویسندگان
چکیده
PURPOSE To investigate patients' perception of glaucomatous VF loss and its association with glaucoma severity using the Amsler grid test. METHODS In this prospective cross-sectional study, glaucoma patients with abnormal 10-2 Humphrey Swedish Interactive Threshold Algorithm-standard VF tests were enrolled consecutively. All patients underwent a black-on-white Amsler grid test for each eligible eye. They were asked to outline any perceived scotomas (areas with abnormal grid lines) on the grid and then describe verbally their perception of the scotomas. Examiners asked patients to clarify their descriptions. All descriptions used by patients were recorded in their own words, which were then sorted into descriptor categories according to similar themes. The number of descriptor categories was counted for each eye. 10-2 VF mean deviation (MD) was compared among eyes that reported different number of descriptor categories. The mean 10-2 VF MD values were compared among different descriptor categories. RESULTS Fifty glaucoma patients (88 eyes) were included. Patients used a total of 44 different descriptors for their scotomas. Patients' descriptors were classified into categories that incorporated similar themes, resulting in 4 overarching descriptor categories: Missing/White, Blurry/Gray, Black, and Not Aware. Fifty-two eyes reported one descriptor category and 19 eyes reported two descriptor categories (mean number of descriptor categories = 1.27±0.45). Eyes that reported two descriptor categories had worse VF MD than those that reported one (-17.86±10.31 dB vs. -12.08±7.53 dB; p = 0.012). When eyes were organized according to its combination of descriptor categories, each eye naturally sorted into one of the following 5 groups, in frequency order: Missing/White (27 eyes; 31%), Blurry/Gray (21 eyes; 24%), combined Missing/White and Blurry/Gray (19 eyes; 21%), Not Aware (17 eyes; 19%), and Black (4 eyes; 5%). The mean 10-2 VF MD severity order was Black (-21.18±10.59 dB), combined Missing/White and Blurry/Gray (-17.86±10.31 dB), Missing/White (-11.92±6.76 dB), Blurry/Gray (-10.55±7.03 dB), and Not Aware (-3.91±4.05 dB) (p<0.001). CONCLUSION Paracentral vision loss in glaucoma is perceived by patients. As the perception of scotomas and the variety of terms to describe scotomas are related to glaucoma severity, clinicians should pay attention to patients' subjective descriptions of their glaucomatous VF loss. The historical notion that glaucoma patients lose their peripheral vision first and eventually look through a black tunnel needs to be updated to reflect the true perception of glaucoma.
منابع مشابه
Novel 3D computer-automated threshold Amsler grid visual field testing of scotomas in patients with glaucoma.
PURPOSE Three-dimensional (3D) computer-automated threshold Amsler grid testing was used to identify and characterize scotomas typical of glaucoma. METHODS The 3D test exhibits a grid on a computer screen at a preselected grayscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. Eleven eyes in patients w...
متن کاملInvestigating the effects of glaucomatous (POAG) damage on the mVEP parameters
Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...
متن کاملNovel 3 D Computerized Threshold Amsler Grid Test
Purpose: To introduce a novel 3D computerized threshold Amsler grid test, developed by Fink and Sadun, that allows for a novel characterization of the structure of visual field defects in three dimensions (see http://www.wfbabcom5.com/wf335.htm). Methods: With one eye covered, patients are placed in front of a computer monitor displaying an Amsler grid. While focusing on a varying central fixat...
متن کاملDistinguishing wet from dry age-related macular degeneration using three-dimensional computer-automated threshold Amsler grid testing.
BACKGROUND/AIMS With the increased efficacy of current therapy for wet age-related macular degeneration (AMD), better ways to detect wet AMD are needed. This study was designed to test the ability of three-dimensional contrast threshold Amsler grid (3D-CTAG) testing to distinguish wet AMD from dry AMD. METHODS Conventional paper Amsler grid and 3D-CTAG tests were performed in 90 eyes: 63 with...
متن کاملRETINAL DISORDERS Quantitative analysis of central visual field defects in macular edema using three-dimensional computer-automated threshold Amsler grid testing
Purpose To evaluate the central visual field (CVF) with specialized Amsler grid testing methods that include contrast sensitivity evaluation, in an attempt to detect abnormalities not identified with standard methods and to define new patterns of CVF deficits in two different diseases. Methods 3D computer-automated threshold Amsler grid testing (3D-CTAG) was performed at five levels of contrast...
متن کامل