Utility of paired BACTEC MYCO/F LYTIC blood culture vials for detection of bacteremia, mycobacteremia, and fungemia.

نویسندگان

  • L K Archibald
  • H Dobbie
  • P Kazembe
  • O Nwanyanwu
  • C McKnight
  • T Byrne
  • R M Addison
  • M Bell
  • L B Reller
  • W R Jarvis
چکیده

In previous bloodstream infection studies in Malawi, we inoculated blood from a single venesection into a single BACTEC MYCO/F LYTIC (MFL) vial. Inoculation of one vial, however, would be expected to reduce the sensitivity of bloodstream pathogen detection with MFL vials. To ascertain the degree of this loss of sensitivity, blood was drawn from each of 228 febrile, adult inpatients in Malawi and 5 ml of each blood sample was inoculated into each of two MFL vials. Of 228 paired vials, 51 (22%) were both positive, 172 (75%) were both negative, and 5 (3%) had discordant results. Bloodstream infection would have been detected in 11 (92%) of 12 patients with mycobacteremia and 38 (92%) of 41 patients with bacteremia had only one MFL vial been inoculated. Our study shows that a second MFL vial does not significantly increase diagnostic sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled comparison of BACTEC 13A, MYCO/F LYTIC, BacT/ALERT MB, and ISOLATOR 10 systems for detection of mycobacteremia.

To compare the performance of the BACTEC 13A (Becton Dickinson, Sparks, Md.), BACTEC MYCO/F LYTIC (Becton Dickinson), BacT/ALERT MB (bioMérieux, Durham, N.C.), and ISOLATOR 10 lysis-centrifugation (Wampole Laboratories, Cranbury, N.J.) systems for detection of mycobacteremia in adults, we inoculated 5-ml aliquots of blood from patients with suspected mycobacteremia into the bottle or tube requi...

متن کامل

Controlled comparison of BacT/Alert MB system, manual Myco/F lytic procedure, and isolator 10 system for diagnosis of Mycobacterium tuberculosis Bacteremia.

We compared the performance of the BacT/Alert MB system, that of the manual Bactec Myco/F Lytic procedure, and that of the Isolator 10 lysis-centrifugation system in the detection of Mycobacterium tuberculosis bacteremia. Mean times to detection were 16.4 days for BacT/Alert MB versus 20.0 days for Myco/F Lytic, 16.5 days for BacT/Alert MB versus 23.8 days for Isolator 10, and 21.1 days for Bac...

متن کامل

Comparison of BACTEC MYCO/F LYTIC and WAMPOLE ISOLATOR 10 (lysis-centrifugation) systems for detection of bacteremia, mycobacteremia, and fungemia in a developing country.

In less-developed countries, studies of bloodstream infections (BSI) have been hindered because of the difficulty and costs of culturing blood for bacteria, mycobacteria, and fungi. During two study periods (study period I [1997] and study period II [1998]), we cultured blood from patients in Malawi by using the BACTEC MYCO/F LYTIC (MFL), ISOLATOR 10 (Isolator), Septi-Chek AFB (SC-AFB), and Sep...

متن کامل

A dedicated fungal culture medium is useful in the diagnosis of fungemia: a retrospective cross-sectional study

BACKGROUND Mortality for candidemia ranges from 15% to 35%. Current guidelines recommend inoculating blood into three aerobic and three anaerobic blood culture bottles when candidemia is suspected, without mention of a fungal blood culture bottle. OBJECTIVE To determine the value of the BACTEC Myco/F Lytic blood culture media in the diagnosis of fungemia. METHODS A two-year retrospective cr...

متن کامل

Controlled evaluation of the agar-slide and radiometric blood culture systems for the detection of bacteremia and fungemia.

A commercially available agar-slide blood culture bottle (Septi-Chek; Roche Diagnostics, Div. Hoffman-La Roche, Inc., Nutley, N.J.) was compared with the radiometric blood culture system (BACTEC; Johnston Laboratories, Inc., Towson, Md.) in 8,544 paired blood cultures from adult patients. The systems were inoculated with equal volumes (10 ml) of blood. Overall, there was no statistically signif...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 39 5  شماره 

صفحات  -

تاریخ انتشار 2001