Spread Funci ' Ion Estimation of Image Intensifier Tub

نویسندگان

  • Edward R. Doering
  • Joseph Gray
  • John P. Basart
چکیده

Real-time radiography systems employing an image intensifier tube have poor resolution (2 to 4Ip/mm) compared to their film-based counterparts (10 to 20 lp/mm). Phosphor bloom, especially in the output conversion phosphor [1], is the principle cause of reduced resolution. Other systems achieve higher resolution but at the expense of additional hardware complexity [2] or use of expensive materials [3]. We are investigating software-based image restoration techniques that can cost-effectively re cover resolution from existing image intensifier tube-based systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AN IMAGE INTENSIFIER-SCINTILLATOR DEVICE FOR DETERMINATION OF PROFILES AND IMAGES OF WEAK BEAMS OF IONIZING PARTICLES OR X-RAYSf

An ins t rument for determining the shape and in tens i ty distribut ion of particle and X-ray beams has been developed using an image intensifier tube together wi th a bundle of filaments of scintillator. A description of the use of such a device in high energy, low intensity, secondary meson and proton beams is given. I t is shown t h a t the sensi t ivi ty of th is instrumen t represents a s...

متن کامل

Compputerized Station for Semi-automated Testing Image Intensifier Tubes

Testing of image intensifier tubes is still done using mostly manual methods due to a series of both technical and legal problems with test automation. Computerized stations for semi-automated testing of IITs are considered as novelty and are under continuous improvements. This paper presents a novel test station that enables semiautomated measurement of image intensifier tubes. Wide test capab...

متن کامل

DEALING ~TH TEC~CAL PROBLEMffi RELATING TO THE PRODUCTS, PROCESSES AND INVESTIGATIONS OF THE PHILIPS INDUSTRIES

For many years electronics has been engaged in the problems of amplifying very weak currents and voltages. In rece~t years, partly owing to the stimulus of teleuision, a new branch of,electronies, that"'is, the intensification. of light, has ·emerged. The original object of this development was the conversion of long-wave; into short-wave light ("wavelength-transformation") which was investigat...

متن کامل

Optimum decoder for multiplicative spread spectrum image watermarking with Laplacian modeling

This paper investigates the multiplicative spread spectrum watermarking method for the image. The information bit is spreaded into middle-frequency Discrete Cosine Transform (DCT) coefficients of each block of an image using a generated pseudo-random sequence. Unlike the conventional signal modeling, we suppose that both signal and noise are distributed with Laplacian distribution, because the ...

متن کامل

The new ProfileView Software for Beam Induced Fluorescence Monitors

GSI accelerators are currently equipped with four Beam Induced Fluorescence (BIF) monitors. They determine the transverse beam profiles without beam disturbance by detecting the fluorescence light generated by excitation of a working gas (N2) with the passing ion beam. Therefore, they are well suited to observe the beam at multiple positions simultaneously [1]. The fluorescence photons are dete...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012