Intraocular lens power calculation for planned ametropia: a clinical study.
نویسنده
چکیده
A prospective series of 25 eyes received an intraocular lens (IOL) of power calculated for planned ametropia, by means of the formulae of R. D. Binkhorst, from data of axial length, corneal curvature, and postoperative anterior chamber depth. All the postoperative refractions were within the +/- 2 D range from the predicted refraction, confirming the clinical value of such calculation. A retrospective study of 100 eyes which had received a +19 D power Binkhorst IOL showed a wide range of change in refraction extending up to the +/- 6 D range, indicating that a 'standard' power IOL cannot be relied upon to reproduce the preoperative refraction. Calculation of IOL power from biometric data is essential when controlled postoperative ametropia is required.
منابع مشابه
Intraocular lens power calculation for emmetropia: a clinical study.
A series of 50 eyes received an intraocular lens (IOL) of power calculated for emmetropia from data of axial length, corneal curvature, and postoperative anterior chamber depth by R. D. Binkhorst's formulae. The postoperative refraction results were compared with those of 100 control eyes which received +19 D standard power IOLs without calculation. The calculated group had postoperative refrac...
متن کاملComparison of intraocular lens power calculation using the Binkhorst and SRK formulae: a clinical study.
Comparison of results of intraocular lens implants with IOL powers obtained by Binkhorst and SRK Linear Regression formulae was done using various models and brands of intraocular lenses. Of 887 pseudophakic patients. 415 patients received IOL's with their powers calculated for planned emmetropia, by means of theoretic formula devised by R.D. Binkhorst and in the remaining 472 eyes the IOL powe...
متن کاملمقایسهی کراتومتری پنتاکم وکراتومتری IOL Master در محاسبهی لنز داخل چشمی افراد با قرنیهی طبیعی
Background and Objective: Proper method and machine for corneal evaluation is an important factor in many anterior segment interventions. This study was performed to compare the mean keratometry (K) readings obtained with an IOL Master and Pentacam for intraocular lens power calculation in normal subjects with no history of refractive surgery. Materials and Methods: Mean K values were obtained ...
متن کاملOrbscan II-assisted intraocular lens power calculation for cataract surgery following myopic laser in situ keratomileusis (an American Ophthalmological Society thesis).
PURPOSE This study tests the hypothesis that the keratometric value derived from Orbscan II mean power maps, when used in an intraocular lens (IOL) calculation formula, at a specific measurement zone, will accurately determine the power of an IOL for planned cataract surgery in patients who have undergone prior myopic laser-assisted in situ keratomileusis (LASIK). METHODS This is a two-part s...
متن کاملSurgical options for correction of refractive error following cataract surgery
Refractive errors are frequently found following cataract surgery and refractive lens exchange. Accurate biometric analysis, selection and calculation of the adequate intraocular lens (IOL) and modern techniques for cataract surgery all contribute to achieving the goal of cataract surgery as a refractive procedure with no refractive error. However, in spite of all these advances, residual refra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 67 4 شماره
صفحات -
تاریخ انتشار 1983