Estimating the radiation absorbed by a human.

نویسندگان

  • Natasha A Kenny
  • Jon S Warland
  • Robert D Brown
  • Terry G Gillespie
چکیده

The complexities of the interactions between long- and short-wave radiation fluxes and the human body make it inherently difficult to estimate precisely the total radiation absorbed (R) by a human in an outdoor environment. The purpose of this project was to assess and compare three methods to estimate the radiation absorbed by a human in an outdoor environment, and to compare the impact of applying various skin and clothing albedos (alpha ( h )) on R. Field tests were conducted under both clear and overcast skies to evaluate the performance of applying a cylindrical radiation thermometer (CRT), net radiometer, and a theoretical estimation model to predict R. Three albedos were evaluated: light (alpha ( h ) = 0.57), medium (alpha ( h ) = 0.37), and dark (alpha ( h ) = 0.21). During the sampling periods, the range of error between the methods used to estimate the radiation absorbed by a cylindrical body under clear and overcast skies ranged from 3 to 8%. Clothing and skin albedo had a substantial impact on R, with the mean change in R between the darkest and lightest albedos ranging from 115 to 157 W m( - 2) over the sampling period. Radiation is one of the most important variables to consider in outdoor thermal comfort research, as R is often the largest contributor to the human energy balance equation. The methods outlined and assessed in this study can be conveniently applied to provide reliable estimates of the radiation absorbed by a human in an outdoor environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of human absorbed dose from [153Sm]-Samarium maltolate based on distribution data in rats

Background: Therapeutic radiopharmaceuticals are designed to deliver high doses of radiation to selected target organs with an aim of minimizing unwanted radiation to surrounding healthy tissue. Due to the potential of targeted radiotherapy to treat a wide range of malignant conditions, [153Sm]-samarium maltolate was developed for possible therapeutic applications. Materials and Methods: The or...

متن کامل

Estimating the Absorbed Dose of Organs in Pediatric Imaging of 99mTc-DTPA Radiopharmaceutical using MIRDOSE Software

Introduction: In this study, organ radiation doses were calculated for the renal agent 99mTc-DTPA in children. Bio-kinetic energy of 99mTc-DTPA was evaluated by scintigraphy and estimates for absorbed radiation dose were provided using standard medical internal radiation dosimetry (MIRD) techniques.Material and Methods: In this applied research, fourteen children patients (6 males and 8 females...

متن کامل

Estimating radiation dose from building materials

Background: Natural radioactivity in materials under certain conditions can reach the hazardous radiological levels. So, it becomes necessary to study the natural radioactivity in different materials to assess the dose for the population in order to know the health risks and to have a baseline for future changes in the environmental radioactivity due to human activities. Materials and ...

متن کامل

Designing CT scanning rooms and estimating patient and personnel absorbed dose using code (MCNPX 2.6)

One of the most widely used diagnostic devices in medical imaging is computed tomography scanning with the use of X-ray ionization. After years of using this tool in the diagnosis and treatment, external doses of these beams can pose a risk of secondary cancer, which is significant in terms of radiation safety and protection. In this paper, using the Monte Carlo code MCNPX2.6 performed over thr...

متن کامل

Evaluation of the dose and flux of secondary particles in the lung tissue in breast proton therapy using the Monte Carlo simulation code

Unlike proton therapy, conventional radiation therapy directs X-rays not only at the tumor but also unavoidably at nearby healthy tissue. Protons deliver radiation to tumor tissue while the healthy structures will be spared during proton therapy. When protons travel through matter, secondary particles like neutrons and photons are produced. It is believed that the secondary dose can lead to sec...

متن کامل

InRaDoS: An internal radiation dosimetry computer program

Introduction: Internal radiation dosimetry is important from a radiation protection point of view and can help to optimize the radiation dose delivered to the workers, public, and patients. It has a rather simple protocol but needs a large amount of data. Therefore, it is difficult to do on a routine basis. The use of computer programs makes internal radiation dosimetry simpler...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of biometeorology

دوره 52 6  شماره 

صفحات  -

تاریخ انتشار 2008