Stabilisation of medically refractory ventricular arrhythmia by intra-aortic balloon counterpulsation.
نویسندگان
چکیده
OBJECTIVE To review the efficacy of intra-aortic balloon counterpulsation (IABCP) in medically refractory ventricular arrhythmia. DESIGN Retrospective analysis of the outcome of patients with ventricular arrhythmia treated with IABCP after transfer between 1992 and 1997. SETTING Tertiary cardiac referral centre. PATIENTS 21 patients (mean age 58 years) who underwent IABCP for control of ventricular arrhythmia. All had significant left ventricular impairment (mean ejection fraction 28.6%); 18 had coronary artery disease. RESULTS Before IABCP, 10 patients had incessant monomorphic ventricular tachycardia and 11 had paroxysmal ventricular tachycardia and/or ventricular fibrillation (VT/VF). IABCP resulted in suppression of ventricular arrhythmia in 18 patients, of whom 13 were weaned from IABCP. After stabilisation of ventricular arrhythmia, 10 patients were maintained on medical treatment alone and one underwent endocardial resection. IABCP was maintained until cardiac transplantation in five patients. One patient had a fatal arrest before discharge and one died from progressive heart failure. IABCP failed to control ventricular arrhythmia in three patients and was subsequently discontinued. A cardiac assist device was employed in one of these until cardiac transplantation; the other two were eventually stabilised on medical treatment. Nineteen patients were discharged from hospital. Overall survival was 95% at mean follow up of 25.7 months. CONCLUSIONS IABCP can be an effective means of controlling refractory ventricular arrhythmia, allowing time for the institution of more definitive treatment.
منابع مشابه
Staphylococcus aureus bacteremia associated with intra-aortic balloon pumps.
To the Editor: Since its first clinical use in the late 1960s, intra-aortic balloon pump counterpulsation has been a significant means of supporting an inadequate myocardium.' The use of an intra-aortic balloon pump has increased greatly preceding open heart surgery for cardiogenic shock and left ventricular failure. Additional indications include other conditions such as unstable angina refrac...
متن کامل[Left ventricular rupture of mitral valve prosthesis implantation treated using an intra-aortic balloon pump counterpulsation].
Left ventricular rupture is an infrequent but potentially fatal complication of mitral valve replacement. In spite of the fact that several methods of repair have previously been described, the mortality rate remains nearly 85%. The use of the intra-aortic balloon pump counterpulsation may increase the possibilities of success in the repair of this dreaded complication. We present here three ca...
متن کاملSuccessful use of intra-aortic counter pulsation therapy for intractable ventricular arrhythmia in patient with severe left ventricular dysfunction and normal coronary arteries.
Intra-aortic balloon pumps (IABP) are commonly used in the setting of an acute myocardial infarction that is complicated by cardiogenic shock or mechanical complications such as a ventricular septal defect or papillary muscle rupture. IABP has also been shown to be useful in patients with refractory and hemodynamically unstable ventricular arrhythmias and refractory post-myocardial infarction a...
متن کاملUnilateral Headache Status after Intra-Aortic Balloon Pump Placement
INTRODUCTION Intra-aortic balloon pump (IABP) counterpulsation is a catheter-based treatment for coronary artery disease and decompensated heart failure to increase coronary blood flow and improve cardiac output. IABP is generally well tolerated, and complications are usually related to peripheral vasculature or red blood cell and platelet consumption. The usual insertion site via femoral arter...
متن کاملProlonged circulatory support with the intra-aortic balloon pump after myocardial infarction.
Circulation was supported by intra-aortic balloon counterpulsation for 30 and 38 days respectively in two patients with cardiogenic shock after acute myocardial infarction. One was flown 1400 km to Cape Town for heart transplantation but died after being weaned from the pump while awaiting a suitable donor. The other underwent successful surgical closure of a ruptured ventricular septum on the ...