Evaluation of base materials of TL slab dosimeter for heavy-ion radiotherapy

نویسندگان

  • Yusuke Koba
  • Kiyomitsu Shinsho
  • Satoshi Tamatsu
  • Shigekazu Fukuda
  • Genichiro Wakabayashi
چکیده

In order to measure a three-dimensional dose distribution in X-ray radiotherapy, we developed TL slab dosimeter with new TL phosphor Li3B7O12(Cu), which has Zeff = 7.42 and a density of 1.01 g/cm 3 and synthetic resin as binder [1].We can measure a three-dimensional dose distribution easily and reliably using this detector. This detector showed a promising tool for QA/QC in advanced X-ray radiotherapies such as IMRT, etc. In heavy-ion radiotherapies which shape precipitous dose distributions, it is also necessary to measure threedimensional dose distribution easily. To use TL slab dosimeter in heavy-ion dosimetry, it is essential to measure its LET dependence sufficiently. And it is necessary to evaluate the dosimetric water equivalence of this dosimeter for heavy ions. Previous studies showed that the relative TL efficiency of this TL phosphor decreased to ~20% at the Bragg-peak of carbon 290 MeV/u beams and the stopping-power ratio of this dosimeter to water for carbon ions was 0.87 [2]. These results were not good for application in heavy-ion radiotherapy. It was often reported that there is a relationship between the glow curve shape of general TLDs (such as LiF and BeO) and LET. Using this relationship of glow curve and LET, the relative TL efficiency can be corrected and we could apply TLDs to dose measurement in heavy-ion radiotherapies. In this study, in order to develop better TL slab dosimeter for heavy-ion radiotherapy using TL phosphors with the above characteristics, we evaluated the dosimetric water equivalence of several base materials for TL slab dosimeter. We chose several kinds of ceramics with heating resistance as the base material; ISOPLATON E3, P1, M2, A98 S1 and Machinable Ceramics, TBS N64, N66, N1, N3 (ISOLITE Co., Ltd). We focused attention on stopping power, scattering power and nuclear cross-section of these materials for heavy ions. We calculated these interactions using the Bethe formula, the Gottschalk formula and the Sihver formula. Figure 1 shows the result of theoretical calculation of the water-equivalence ratio, stopping power ratio S/Sw, scattering power ratio T/Tw and nuclear cross-section ratio σ/σw for carbon-ion beam. In these ceramics, ISOPLANTON S1 was the best of base material for TL slab dosimeter for carbon-ion beam. On the basis of this evaluation, we will develop the TL slab dosimeter for heavy-ion radiotherapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sintered Al2O3 based Materials for Radiotherapy Thermoluminescent Dosimeter Applications

INTRODUCTION The thermoluminescent (TL) properties of various materials have been studied since a long time but many of these developments never reach the thermoluminescent dosimeter (TLD) users. α-Al2O3:C TL detectors were first developed and produced at Urals Polytechnical Institute ( UPI ) (1) in the form of a single crystal. These TLD ( model 2600 – 80 ) are now supplied by Victoreen to man...

متن کامل

A Dosimetric Evaluation of Organs at Risk in Prostate Radiation Therapy using a MAGIC Gel Dosimeter

Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made....

متن کامل

Evaluation of dose distribution of 12C ion beam in radiotherapy by FLUKA as a Monte Carlo simulation Code

Introduction: Nowadays, the use of heavy ion beams in cancer therapy have been developed worldwide.   Materials and Methods: It requires accurate understanding of the complex processes of ion interaction with matter, as it is the calculation the relative dose & range of these ions in matter. In the present study we used FLUKA as a numerical Monte Carlo simula...

متن کامل

اندازه‌گیری دز گامای ایجاد شده توسط نوترون‌های حرارتی در دزسنج‌TLD-700

Neutron response Induced in Thermoluminescence Dosimeter TLD-700 chips due to reactions of thermal neutrons with slab phantom and Badge Dosimeter TLD-600,700 materials in a neutron-gamma mixed field was measured. Using the linear relationship between thermal neutron fluence and the thermal neutrons induced TL response with slab phantom, Badge-TLD Materials, an empirical relationship was introdu...

متن کامل

Evaluation of Gold Nanoparticle Size Effect on Dose Enhancement Factor in Megavoltage Beam Radiotherapy Using MAGICA Polymer Gel Dosimeter

Background: Gold nanoparticles (GNPs) are among the most promising radiosensitive materials in radiotherapy. Studying the effective sensitizing factors such as nanoparticle size, concentration, surface features, radiation energy and cell type can help to optimize the effect and possible clinical application of GNPs in radiation therapy. In this study, the radiation sensitive polymer gel was use...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2014