A method to individualize adaptive planning target volumes for deformable targets.

نویسندگان

  • Pauliina Wright
  • Anthony Thomas Redpath
  • Morten Høyer
  • Ludvig Paul Muren
چکیده

We have investigated a method to individualize the planning target volume (PTV) for deformable targets in radiotherapy by combining a computer tomography (CT) scan with multiple cone beam (CB)CT scans. All combinations of the CT and up to five initial CBCTs were considered. To exclude translational motion, the clinical target volumes (CTVs) in the CBCTs were matched to the CTV in the CT. PTVs investigated were the unions, the intersections and all other structures defined by a volume with a constant CTV location frequency. The method was investigated for three bladder cancer patients with a CT and 20-27 CBCTs. Reliable alternatives to a standard PTV required use of at least four scans for planning. The CTV unions of four or five scans gave similar results when considering the fraction of individual repeat scan CTVs they volumetrically covered to at least 99%. For patient 1, 64% of the repeat scan CTVs were covered by these unions and for patient 2, 86% were covered. Further, the PTVs defined by the volume occupied by the CTV in all except one of the four or five planning scans seemed clinically feasible. On average, 52% of the repeat CBCT CTVs for patient 1 and 64% for patient 2 were covered to minimum 99% of their total volume. For patient 3, the method failed due to poor volume control of the bladder. The suggested PTVs could, with considerably improved conformity, complement the standard PTV.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Target Detection in Bistatic Passive Radars by Using Adaptive Processing Based on Correntropy Cost Function

In this paper a novel method is introduced for target detection in bistatic passive radars which uses the concept of correntropy to distinguish correct targets from false detections. In proposed method the history of each cell of ambiguity function is modeled as a stochastic process. Then the stochastic processes consist the noise are differentiated from those consisting targets by constructing...

متن کامل

A Laplacian Surface Deformation and Optimization Based 3D Registration Algorithm for Image Guided Prostate Radiotherapy

Purpose: To develop a fast landmark-based deformable registration method to capture the soft tissue transformation between the planning 3D CT images and treatment 3D cone-beam CT (CBCT) images for the adaptive external beam radiotherapy (EBRT). Method and Materials: The developed method was based on a global-to-local landmark-based deformable registration algorithm. The landmarks were first acq...

متن کامل

The Role of MRSI in Target Volume Definition for Radiation Therapy of Prostate Cancer

Introduction: Recently, magnetic resonance spectroscopic imaging (MRSI), as a functional imaging method, has been used for clinical target volume definition. In this study, we used this method to define the target volume in prostate radiotherapy. Material and Method: In this study, we used images of 20 prostate cancer cases. MRSI and MRI images were fused with CT images. Then, treatment plannin...

متن کامل

A Novel Method for Detecting Targets on Inactive Radars Using an Adaptive Processing on the Ambiguity Function (RESEARCH NOTE)

In this paper a novel method for detecting targets in inactive radars is presented. In this method, the time history of cellsof the ambiguity function is used for detection. For this purpose, the cell history is considered as a random field. Then, using adaptive filter, the string time of the desired target are separated from the string time of noise and clusters in the environment. In order to...

متن کامل

Comparative evaluation of target volumes defined by deformable and rigid registration of diagnostic PET/CT to planning CT in primary esophageal cancer

BACKGROUND To evaluate the geometrical differences of target volumes propagated by deformable image registration (DIR) and rigid image registration (RIR) to assist target volume delineation between diagnostic Positron emission tomography/computed tomography (PET/CT) and planning CT for primary esophageal cancer (EC). METHODS Twenty-five patients with EC sequentially underwent a diagnostic F-f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 54 23  شماره 

صفحات  -

تاریخ انتشار 2009