Four-Dimensional CT of the Diaphragm in Children: Initial Experience
نویسنده
چکیده
Objective To evaluate the technical feasibility of four-dimensional (4D) CT for the functional evaluation of the pediatric diaphragm. Materials and Methods In 22 consecutive children (median age 3.5 months, age range 3 days-3 years), 4D CT was performed to assess diaphragm motion. Diaphragm abnormalities were qualitatively evaluated and diaphragm motion was quantitatively measured on 4D CT. Lung density changes between peak inspiration and expiration were measured in the basal lung parenchyma. The diaphragm motions and lung density changes measured on 4D CT were compared between various diaphragm conditions. In 11 of the 22 children, chest sonography was available for comparison. Results Four-dimensional CT demonstrated normal diaphragm (n = 8), paralysis (n = 10), eventration (n = 3), and diffusely decreased motion (n = 1). Chest sonography demonstrated normal diaphragm (n = 2), paralysis (n = 6), eventration (n = 2), and right pleural effusion (n = 1). The sonographic findings were concordant with the 4D CT findings in 90.9% (10/11) of the patients. In diaphragm paralysis, the affected diaphragm motion was significantly decreased compared with the contralateral normal diaphragm motion (-1.1 ± 2.2 mm vs. 7.6 ± 3.8 mm, p = 0.005). The normal diaphragms showed significantly greater motion than the paralyzed diaphragms (4.5 ± 2.1 mm vs. -1.1 ± 2.2 mm, p < 0.0001), while the normal diaphragm motion was significantly smaller than the motion of the contralateral normal diaphragm in paralysis (4.5 ± 2.1 mm vs. 7.6 ± 3.8 mm, p = 0.01). Basal lung density change of the affected side was significantly smaller than that of the contralateral side in diaphragm paralysis (89 ± 73 Hounsfield units [HU] vs. 180 ± 71 HU, p = 0.03), while no significant differences were found between the normal diaphragms and the paralyzed diaphragms (136 ± 66 HU vs. 89 ± 73 HU, p = 0.1) or between the normal diaphragms and the contralateral normal diaphragms in paralysis (136 ± 66 HU vs. 180 ± 71 HU, p = 0.1). Conclusion The functional evaluation of the pediatric diaphragm is feasible with 4D CT in select children.
منابع مشابه
EVENTRATION OF THE DIAPHRAGM: A 10- YEAR EXPERIENCE
Eventration of the diaphragm is a condition characterized by an attenuated but otherwise intact diaphragm. Twenty patients (age range: 2 days to 11 years) were treated for eventration of the diaphragm during a ten year period (19 85-1995). There were 11 girls and 9 boys with a mean gestational age of 37 weeks. 14 patients were born with cephalic presentation, 3 patients with breech deliver...
متن کاملO18: In Hospital Management of Child with Road Trauma
Trauma is the most common cause of mortality and morbidity in pediatric population. Caring for the injured child requires special knowledge, precise management, and scrupulous attention to details. All clinicians who are responsible for the care of a pediatric trauma patient, including pediatricians, pediatric emergency room clinicians, and trauma surgeons, must be familiar with every tenet of ...
متن کاملClinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment
Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...
متن کاملCan we save our resources with half-body-18F-FDG-PET-CT rather than whole-body, in the management of head & neck cancers?
Methods A 6-year-period retrospective analysis of 729 consecutive PET-CT scans of H&N cancer patients was performed in order to record the incidence of below-diaphragm metastases and below-diaphragm synchronous primary malignancies. The four main indications of PET-CT in H&N cancers are; pre-treatment staging of high-risk of disseminated disease, metastatic cervical lymphadenopathy with unknown...
متن کاملDesign and Fabrication of a Four-Dimensional Respiratory Phantom for Studying Tumor Movement in Radiotherapy with Magnetic Resonance Imaging
Introduction: In radiation therapy, determining the location of the tumor accurately during irradiation is one of the most important requirements. However, lung tumors are not fixed in a single location and move during irradiation due to respiratory motion. Due to limitations in assessing such movements, using a lung phantom can be useful and operational for their fast, easy an...
متن کامل