The measurements of thermal neutron flux distribution in a paraffin phantom
نویسندگان
چکیده
The term ‘thermal flux’ implies a Maxwellian distribution of velocity and energy corresponding to the most probable velocity of 2200 m s−1 at 293.4 K. In order to measure the thermal neutron flux density, the foil activation method was used. Thermal neutron flux determination in paraffin phantom by counting the emitted rays of indium foils with two different detectors (Geiger– Muller counter and NaI(Tl)) was the aim of this project. The relative differences of the outcome of the experiments were between 2.5% and 5%. The final results were compared with MCNP4C outputs and the best agreement was generated using NaI(Tl) by a minimum discrepancy of about 0.6% for the foil placed 8.5 cm from the neutron source.
منابع مشابه
The influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method
Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...
متن کاملEstimation of neutron effective dose from DD and DT neutron generators and the design of appropriate shield for standing user
Neutron Generators (NG) are used as a neutron source for different applications. During recent years, major efforts are underway to develop a high yield compact NG. In this way, radiation protection aspects need to be considered during the operation of these high yield NGs. In this paper the neutron effective dose of a NG operator has been calculated using MCNPX Monte Carlo code. The results sh...
متن کامل10B Concentration, Phantom Size and Tumor Location Dependent Dose Enhancement and Neutron Spectra in Boron Neutron Capture Therapy
Background: The amount of average dose enhancement in tumor loaded with 10B may vary due to various factors in boron neutron capture therapy.Objective: This study aims to evaluate dose enhancement in tumor loaded with 10B under influence of various factors and investigate the dependence of this dose enhancement on neutron spectra changes.Material and Methods: In this simulation stud...
متن کاملشبیهسازی مونت کارلو یک دستگاه پرتودهی نوترونی به منظور تعیین بازده آشکارسازهای نوترونهای حرارتی
In this work, a neutron irradiating system containing six Am/Be neutron sources in a graphite moderator, which produces a relatively high and uniform thermal neutron flux in an irradiating cavity at the center of the system , has been simulated .The thermal neutron flux in the center of the system has then been calculated and compared with experimental results measured in a cavity a...
متن کاملAn investigation into the potential applicability of gel dosimeters for dosimetry in boron neutron capture therapy
Background: The aim of this work was to establish how well gel dosimeters performed, as substitutes for brain tissue compared with standard phantom materials such as water, polymethyl-methacrylate (or PMMA), A150 plastic and TE- liquid phantom material for dosimetry of neutron beams in boron neutron capture therapy. Materials and Methods: Thermal neutron fluence, photon dose and epithermal neu...
متن کاملذخیره در منابع من