Total cardiopulmonary support with disposable membrane oxygenator during aortocoronary artery-vein graft operations.
نویسندگان
چکیده
Fifty-five patients received total cardiopulmonary support with the disposable Lande-Edwards membrane oxygenator during aortocoronary artery-vein graft operations and other complex open heart operations. Two three meter2 membrane oxygenators were linked in parallel to a standard r o b pump apparatus. (Three 3 meter2 membranes for patients weighing 80 to 103 kg.) Excellent oxygen and carbon dioxide exchange (2 ml (h/kg/min) occurred during hypothermia of 30°C at flows of 50 ml/kg/min during pump runs of 1 to 6% hours. Low sonar counts for microemboli were associated with platelet counts up to 200,000 per milliliters; therefore, fewer Mood transfusions were needed. Plasma hemoglobin was below SO mg percent, and the urine remained yellow except when excessive surtioning occurred. Immediate awakening and ambulation in the hallway within 24 hours, reduced lung complications and permitted earlier hospital discharge than similar patients supported with bubble oxygen* tor. The absence of direct Mood gas interface in membrane oxygenator allows safer prolonged total cardiopulmonary support in our hands than the bubble or disc oxygenator.
منابع مشابه
Accelerated intimal hyperplasia in aortocoronary internal mammary vein grafts in minipigs
BACKGROUND More than 50% of aortocoronary saphenous vein grafts are occluded 10 years after surgery. Intimal hyperplasia is the initial critical step in the progression toward occlusion. Internal mammary veins, which are physiologically prone to less hydrostatic pressure, may undergo an accelerated progression to intimal hyperplasia and thus be suitable for investigation of the mechanisms of ao...
متن کاملSurgery for Preinfarction Angina
Immediate relief of anginal pain is the dramatic result of aortocoronary bypass. Initially the operation was performed electively for patients with chronic angina. Subsequently indications for operation were expanded to include patients with constant pain and electrocardiographic changes of impending infarction. These patients with "preinfarction angina" undergo coronary arteriograms, frequentl...
متن کاملAortocoronary bypass grafting in a child with coronary artery obstruction due to mucocutaneous lymphnode syndrome: report of a case.
A four-year-old boy with a myocardial infarct and total occlusion of the right coronary and the left anterior descending coronary arteries due to mucocoutaneous lymphnode syndrome (MCLS). confirmed by selective coronary arteriography, underwent successful double aortocoronary bypass grafting. Patency of the grafts was demonstrated by graft angiography and the improvement of the contractile patt...
متن کاملPartial cardiopulmonary bypass in rats using a hollow fibre oxygenator.
Despite new minimally invasive techniques, cardiopulmonary bypass (CPB) is still necessary for many major operations in the field of cardiac surgery. Unwanted side effects of CPB are well known but poorly understood. We therefore developed a rodent model to study the pathophysiology of these potential complications. Male Fischer rats were anaesthetized, intubated and ventilated. The carotid art...
متن کاملHistological survey of the saphenous vein before its use as autologous aortocoronary bypass graft.
A histological examination has been carried out on the saphenous veins used in 150 consecutive patients undergoing aortocoronary bypass. Morphological changes were observed frequently and consisted mainly of fibrosis of the intima and of the medial longitudinal muscular layer. Intimal fibrosis was rarely severe enough to narrow the lumen significantly. Statistical analysis disclosed that the fi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 62 4 شماره
صفحات -
تاریخ انتشار 1972