Interobserver variations of target volume delineation and its impact on irradiated volume in accelerated partial breast irradiation with intraoperative interstitial breast implant
نویسندگان
چکیده
PURPOSE To investigate the interobserver variations in delineation of lumpectomy cavity (LC) and clinical target volume (CTV), and its impact on irradiated volume in accelerated partial breast irradiation using intraoperative multicatheter brachytherapy. MATERIAL AND METHODS Delineation of LC and CTV was done by five radiation oncologists on planning computed tomography (CT) scans of 20 patients with intraoperative interstitial breast implant. Cavity visualization index (CVI), four-point index ranging from (0 = poor) to (3 = excellent) was created and assigned by observers for each patient. In total, 200 contours for all observers and 100 treatment plans were evaluated. Spatial concordance (conformity index, CIcommon, and CIgen), average shift in the center of mass (COM), and ratio of maximum and minimum volumes (Vmax/Vmin) of LC and CTV were quantified among all observers and statistically analyzed. Variation in active dwell positions (0.5 cm step) for each catheter, total reference air kerma (TRAK), volume enclosed by prescription isodose (V100%) among observers and its spatial concordance were analyzed. RESULTS The mean ± SD CIcommon of LC and CTV was 0.54 ± 0.09, and 0.58 ± 0.08, respectively. Conformity index tends to increase, shift in COM and Vmax/Vmin decrease significantly (p < 0.05), as CVI increased. Out of total 309 catheters, 29.8% catheters had no change, 29.8% and 17.5% catheters had variations of 1 and 2 dwell positions (0.5 cm and 1 cm), respectively. 9.3% catheters shown variations ≥ 10 dwell positions (5 cm). The mean ± SD CIcommon of V100% was 0.75 ± 0.11. The mean observed Vmax/Vmin of prescription isodose and TRAK was 1.18 (range, 1.03 to 1.56) and 1.11 (range, 1.03 to 1.35), respectively. CONCLUSIONS Interobserver variability in delineation of target volume was found to be significantly related to CVI. Smaller variability was observed with excellent visualization of LC. Interobserver variations showed dosimetric impact on irradiation of breast tissue volume with prescription dose.
منابع مشابه
A study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy
Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...
متن کامل3D-conformal Accelerated Partial Breast Irradiation treatment planning: the value of surgical clips in the delineation of the lumpectomy cavity
BACKGROUND Accurate localisation of the lumpectomy cavity (LC) volume is one of the most critical points in 3D-conformal Partial breast irradiation (3D-APBI) treatment planning because the irradiated volume is restricted to a small breast volume. Here, we studied the role of the placement of surgical clips at the 4 cardinal points of the lumpectomy cavity in target delineation. METHODS Forty ...
متن کاملPost-lumpectomy CT-guided tumor bed delineation for breast boost and partial breast irradiation: Can additional pre- and postoperative imaging reduce interobserver variability?
For breast boost radiotherapy or accelerated partial breast irradiation, the tumor bed (TB) is delineated by the radiation oncologist on a planning computed tomography (CT) scan. The aim of the present study was to investigate whether the interobserver variability (IOV) of the TB delineation is reduced by providing the radiation oncologist with additional magnetic resonance imaging (MRI) or CT ...
متن کاملDosimetric considerations and early clinical experience of accelerated partial breast irradiation using multi-lumen applicators in the setting of breast augmentation
PURPOSE Accelerated partial breast irradiation (APBI) is an accepted treatment option in breast-conserving therapy for early stage breast cancer. However, data regarding outcomes of patients treated with multi-lumen catheter systems who have existing breast implants is limited. The purpose of this study was to report treatment parameters, outcomes, and possible dosimetric correlation with cosme...
متن کاملBreast conservation therapy without capsular contracture in young augmented women using interstitial brachytherapy
PURPOSE To describe a breast-conserving technique using interstitial brachytherapy after lumpectomy and axillary nodal sampling in selected women who are diagnosed with breast cancer in the presence of augmentation mammoplasty. MATERIAL AND METHODS Over the past 20 years, we have developed and improved a technique of "pinch view" image-guided catheter insertion that avoids implant puncture. S...