The influence of pH on the leaching behaviour of inorganic components from municipal solid waste APC residues.

نویسندگان

  • Margarida J Quina
  • João C M Bordado
  • Rosa M Quinta-Ferreira
چکیده

The influence of pH on the leaching behaviour of air pollution control (APC) residues produced in municipal solid waste incineration (MSWI) is addressed in this study. The residue is considered hazardous waste, and in accordance with their chemical properties, the leaching of contaminants into the environment is the main concern. Several leaching tests can be used for research studies or regulatory purposes, where a wide variety of conditions may be tested. Our work deals mainly with the leaching behaviour of toxic heavy metals (Pb, Cd, Zn, Cr, Ni, Cu) and inorganics associated with soluble salts (Na, K, Ca, Cl). The main goal is to obtain an overview of the leachability of APC residues produced in a Portuguese MSWI process. Among the different variables that may have influence on the leaching behaviour, pH of the leachant solution is the most important one, and was evaluated through pH static tests. The acid neutralization capacity (ANC) of the residue was also determined, which is in the range of 6.2-6.8 meq g(-1) (for pH=7) and 10.1-11.6 meq g(-1) (for pH=4). The analysis of the leaching behaviour is particularly important when the leaching is solubility controlled. The amphoteric behaviour of some elements was observed, namely for Pb and Zn, which is characterized through high solubilization at low and high pH and moderate or low solubility at neutral or moderate high pH. The solubility curves for Pb, Cd, Zn, Cr, Ni and Cu as a function of pH were obtained, which are very useful for predicting the leaching behaviour in different scenarios. The solubility of K and Na reveals to be nearly independent of the solution pH and the released amount is mainly availability-controlled. Moreover, the pH static test showed that Cl(-) is the most pH-independent species. The APC residue turns out to be a hazardous waste because of the high leaching of lead and chloride. On the other hand, leaching of elements like cadmium, nickel and copper is limited by the high pH of the residue, and as long as the waste keeps its ANC, the risk of mobilization of these elements is low.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influences of ammonia contamination on leaching from air-pollution-control residues.

Application of selective non-catalytic reduction systems at municipal solid waste incinerators (MSWIs) often involves over-stoichiometric injection of ammonia into flue gases. Un-reacted ammonia may be deposited on fly ash particles and can ultimately influence the leaching behaviour of air-pollution-control (APC) residues. Batch tests were conducted to investigate the impacts of ammonia levels...

متن کامل

Environmental Management of Fly Ash Produced from the Incineration of Municipal Solid Waste

Incineration is a widely used and well established technology for the municipal solid waste (MSW) management. Modern MSW incineration plants are equipped with improved air pollution control (APC) systems, which reduce pollutants well below the established limits. The environmental concern has, thus, moved from the air emissions to the solid residues generated from the APC systems of the inciner...

متن کامل

Solidification/stabilisation of air pollution control residues using Portland cement: Physical properties and chloride leaching.

Portland cement (CEMI) was used to solidify air pollution control (APC) residues from an energy-from-waste plant burning municipal solid waste. APC residue/CEMI mixes were prepared with CEMI additions ranging from 0 to 50 weight% (wt%) of total dry mass and water/solids ratios between 0.40 and 0.80. Isothermal conduction calorimetry was used to assess the effect of APC residues on the hydration...

متن کامل

Leaching behaviour of elements and evaluation of pre-treatment methods for municipal solid waste incinerator residues in column leaching tests.

Two new pre-treatment methods (water-washing/carbonation and carbonation/phosphate stabilization) of municipal solid waste (MSW) incinerator residues were evaluated by column leaching tests under aerobic conditions and anaerobic conditions (which were changed to aerobic conditions after 10 months). A mixture of bottom ash and fly ash (5:1 ratio) was pre-treated using each method. Shredded incom...

متن کامل

Leaching Behaviour of Elements and Evaluation of Pre-treatment Methods for Municipal Solid Waste Incinerator (MSWI) Residues in Column Leaching Tests

Two new pre-treatment methods (water-washing/carbonation and carbonation/phosphate stabilisation) of municipal solid waste (MSW) incinerator residues were evaluated by column leaching tests under aerobic conditions and anaerobic conditions (which were changed to aerobic conditions after 10 months). A mixture of bottom ash and fly ash (5:1 ratio) was pre-treated using each method. Shredded incom...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Waste management

دوره 29 9  شماره 

صفحات  -

تاریخ انتشار 2009