Mitigation of Inrush Current of Transformer using Voltage Sag Compensator

نویسنده

  • Raj Kumari
چکیده

In the power system voltage sag become the important issue for industries. According to the survey 92% of the interruptions at industrial installations are voltage sag related. In various companies voltage sag may affect many manufactures and introduce sufficient losses in the power system. The voltage sag compensator, based on a transformer coupled series connected voltage source inverter, is among the most cost-effective solution against voltage sags. A transformer inrush may occur at the start of sag compensator. This over current may damage the inrush protection of the series connected inverter and the transformer output voltage is greatly reduced due the magnetic saturation. When the compensator restores the load voltage, the flux linkage will be driven to the level of magnetic saturation and severe inrush current occurs. This paper proposes a new technique for mitigating the inrush of the coupling transformer and preserving the output voltage for effective

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mitigation Transformer Inrush Current Using Modified Transient Current Limiter

This study presents a modified transient current limiter (MTCL) for mitigation the inrush current of transformers. The MTCL is based on conventional transient current limiter (TCL), which, its configuration is modified to overcome the TCL drawbacks of operation. The proposed MTCL offers lower power losses and voltage/current THD during normal operation mode. It needs only one limiting reactor i...

متن کامل

Voltage Sag Effect on Three Phase Five Leg Transformers

The behavior of three phase five leg transformer under voltage sag is studied in this paper. This paper proposes a simple, practical model of a three phase-five leg, saturated transformer with accurate performance. Transformer saturation is produced when the voltage sag is recovered and it causes inrush current in transformer. Effects of voltage sag depth, duration and initial point on wave hav...

متن کامل

Transformer inrush current mitigation using controlled switching and magnetic flux shunts

The inrush current is a transient current that results from a sudden change in the exciting voltage across a transformer’s windings. It may cause inadvertent operation of the protective relay system and necessitate strengthening of the transformer’s mechanical structure. Many methods were reported in the literatures for reduction and mitigation of transformer inrush currents. This paper represe...

متن کامل

Application of Distribution Static Compensator (D-STATCOM) to Voltage Sag Mitigation

This paper presents a study of a D-STATCOM (Distribution Static Compensator) used for mitigating voltage sag. The basic idea of the voltage sag mitigation, using a D-STATCOM is to dynamically inject a current of desired amplitude, frequency and phase into the grid line. The proposed method extracts the active and reactive parts of the positiveand negative-sequence component for generating refer...

متن کامل

Investigation and Mitigation of Transformer Inrush Current during Black Start of an Independent Power Producer Plant

The energizing of large power transformers has long been considered a critical event in the operation of an electric power system. When a transformer is energized by the utility, a typical inrush current could be as high as ten times its rated current. This could cause many problems from mechanical stress on transformer windings to harmonics injection, and system protection malfunction. There h...