Determination of danshensu in rat plasma and tissues by high-performance liquid chromatography.

نویسندگان

  • Zi-chuan Zhang
  • Man Xu
  • Shi-feng Sun
  • Hui Guo
  • Xue Qiao
  • Jian Han
  • Bao-rong Wang
  • De-an Guo
چکیده

A systematic study on pharmacokinetics and tissue distribution of danshensu (one of the major active components from Salvia miltiorrhizae) is conducted using a rapid and sensitive high-performance liquid chromatographic (HPLC) method. Before HPLC analysis, biological samples are pretreated with a liquid-liquid extraction. Separation of danshensu and internal standard is achieved on an Agilent Zorbax C18 column with a mobile phase made up of acetonitrile and 0.05% trifluoracetic acid at a flow rate of 0.8 mL/min. The calibration curves in plasma and tissues are linear in the given concentration ranges, with r2 no less than 0.99. The intra-day and inter-day relative standard deviations in the measurement of quality control samples are less than 15%, and the accuracies are in the range of 86-115%. The recoveries of danshensu in plasma and tissues are among 80% to 118%. Meanwhile, the multi-peaks in pharmacokinetic profiles are observed. The method is successfully applied to the pharmacokinetics and tissue distribution study of danshensu after a single oral administration of 50.0 mg/kg sodium danshensu to rats.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trace Determination of Duloxetine in Human Plasma by a Novel Ionic Liquid-Based Ultrasound-Assisted In Situ Solvent Formation Microextraction and High-Performance Liquid Chromatography

For the first time, a novel and efficient ionic liquid-based ultrasound-assisted in-situ solvent formation microextraction (IL-UA-ISFME) combined with high-performance liquid chromatography-ultraviolet detection (HPLC-UV) has been successfully developed for the determination of duloxetine (DLX) in human plasma. Herein, an environmentally-friendly hydrophobic ionic liquid (1-butyl-3-methylimidaz...

متن کامل

Lighter than Water Dispersive Liquid-liquid Microextraction Coupled with High Performance Liquid Chromatography for Determination of Cholecalciferol and Calcifediol from Plasma

In this study, a dispersive liquid–liquid microextraction method using an extraction solvent lighter than water has been developed for the extraction and preconcentration of cholecalciferol and calcifediol from plasma samples followed by high performance liquid chromatography determination. Initially, acetonitrile and sodium chloride (NaCl) are added into the plasma as an extraction solvent and...

متن کامل

Vortex-Assisted Inverted Dispersive Liquid-Liquid Microextraction of Naproxen from Human Plasma and Its Determination by High-Performance Liquid Chromatography

Extraction and determination of naproxen from human plasma were performed using Vortex-Assisted Inverted Dispersive Liquid-Liquid MicroExtraction (VA−IDLLME) and High-Performance Liquid Chromatography (HPLC). The parameters affecting extraction recovery such as type and volume of extraction and disperser solvents, pH of sample solution, stirring rate, extraction time and salt addition were ...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 46 2  شماره 

صفحات  -

تاریخ انتشار 2008