Full-Ring Intracorneal Implantation in Corneas With Pellucid Marginal Degeneration

نویسندگان

  • Sahar Mojaled Nobari
  • Consuelo Villena
  • Khosrow Jadidi
چکیده

BACKGROUND Keratoconus (KCN) is a progressive, non-inflammatory ectacic disorder characterized by bilateral and asymmetrical conical protrusion of the cornea. MyoRing implantation and Collagen Crosslink (CXL) are two separate effective treatments for all stages of keratoconous. This study wants to show the effect of these treatments combination in patients with moderate and severe keratoconus. OBJECTIVES The aim of this study was to report on the visual and refractive outcomes of corneas with pellucid marginal degeneration following MyoRing implantation (DIOPTEX GmbH). PATIENTS AND METHODS This study included 15 eyes of 15 patients, with an age range from 22 to 49 years old, and pellucid marginal degeneration. An intrastromal corneal ring (MyoRing) was inserted by the means of mechanical dissection using a PocketMaker microkeratome. The main outcome measures were uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest refraction, and keratometry readings. The mean postoperative follow-up was ten months (range 6 - 12 months). RESULTS The mean UDVA (LogMAR) improved significantly from 1.13 ± 0.21 preoperatively to 0.24 ± 0.13 postoperatively (P < 0.001), and the mean CDVA (LogMAR) improved significantly from 0.39 ± 0.12 to 0.19 ± 0.09 (P < 0.001). The mean cylinder of manifest refraction decreased significantly by 4.00 diopter (D) (P < 0.001). The mean spherical equivalent error (SE) decreased significantly from -6.00 ± 3.60 D to -0.70 ± 1.90 D, at the end of the follow-up period. Furthermore, with regards to corneal topography, a significant reduction was observed in keratometric values. The Kmax, Kmin and Kaverage decreased significantly by 5.00, 1.10 and 4.00 D, respectively (P < 0.001). CONCLUSIONS MyoRing implantation using the PocketMaker microkeratome appears to provide an effective method for treating pellucid marginal degeneration. Both UDVA and CDVA improved significantly. The corneal steepening and astigmatism were reduced in all subjects after MyoRing implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Actual Indications for Intracorneal Ring Segment Implantation in Keratoconus

Intracorneal ring segments (ICRS) are small synthetic implements designed to achieve refractive adjustment by flattening the cornea. Three common types of commercially available ICRS are Intacs, Keraring and Ferrara rings. Low myopia was the initial indication for implantation of ICRS, and indications later included ectatic corneal diseases (such as keratoconus and pellucid marginal degeneratio...

متن کامل

Refractive and corneal aberrometric changes after intracorneal ring implantation in corneas with pellucid marginal degeneration.

PURPOSE To evaluate refractive, visual, and aberrometric changes in corneas with pellucid marginal degeneration (PMD) implanted with intracorneal ring segments (ICRS) during a 6-month follow-up. DESIGN Retrospective, consecutive case series. PARTICIPANTS We included 21 consecutive eyes of 15 patients ranging in age from 21 to 73 years old and with a diagnosis of PMD. This diagnosis was made...

متن کامل

Cataract Extraction and Toric Intraocular Lens Implantation for the Management of Pellucid Marginal Degeneration and Cataract

We report cataract surgery with toric intraocular lens implantation for the management of senile cataract combined with pellucid marginal degeneration. A 72-year-old man with bilateral senile cataract and significant against-the-rule astigmatism sought counseling for blurry vision and glare, mostly in the right eye. Based on ophthalmic examination and corneal topography, a diagnosis of pellucid...

متن کامل

[Pellucid marginal degeneration: diagnosis and treatment].

Pellucid marginal degeneration is characterized by a progressive stromal thinning of the inferior corneal segment, between 4 and 8 o'clock, with a crescentic shape. The area of corneal thinning has a width of about 1 to 2 mm, and it is separated from the corneoscleral limbus by an area of normal corneal tissue. The initial treatment consists of optical correction. However, when the disease prog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2015