Accuracy of cup height and medialization in THA for dysplastic hip osteoarthritis using an imageless navigation system.

نویسندگان

  • Fumiaki Inori
  • Hirotsugu Ohashi
  • Hirotake Yo
  • Yoshiaki Okajima
  • Yoshio Matsui
  • Kousuke Shintani
چکیده

In total hip arthroplasty (THA) for dysplastic hip osteoarthritis, bony deformity makes it difficult to identify the correct cup height and medialization. The authors developed a new technique for registration and navigation of cup position for dysplastic hips using an imageless navigation system. Eighty dysplastic hips (Crowe type I, n=58; type II, n=18; type III, n=4) underwent THA. Thirty-four hips were operated on while in the supine position and 46 hips were operated on while in the lateral position. Before capsulectomy, the anterior pelvic plane and the position of the femur were registered. After exposure of the acetabulum, the teardrop, posterior rim, and medial wall of the acetabulum were registered. Then the cup height, cup medialization, cup inclination, anteversion, and leg lengthening were navigated. The difference between the navigated and radiographic cup heights was 4.5 ± 4.0 mm, the difference in cup medialization was 3.0 ± 2.5 mm, the difference in cup inclination was 4.3° ± 3.1°, the difference in cup anteversion was 5.5° ± 3.8°, and the difference in leg lengthening was 3.7 ± 3.0 mm. Comparison of the first 20 cases with the last 20 cases showed that the accuracy of cup medialization was significantly improved. These differences were not affected by Crowe type or surgical position. Because the correct cup height and medialization are key issues in THA for dysplastic hip osteoarthritis, the accuracy of cup height and medialization in this imageless navigation system were acceptable for clinical application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications

In total hip arthroplasty (THA), the accurate positioning of implants is the key to achieve a good clinical outcome. Computer-assisted orthopaedic surgery (CAOS) has been developed for more accurate positioning of implants during the THA. There are passive, semi-active, and active systems in CAOS for THA. Navigation is a passive system that only provides information and guidance to the surgeon....

متن کامل

Accuracy of acetabular cup positioning using imageless navigation

BACKGROUND Correct placement of the acetabular cup is a crucial step in total hip replacement to achieve a satisfactory result and remains a challenge with free-hand techniques. Imageless navigation may provide a viable alternative to free-hand technique and improve placement significantly. The purpose of this project was to assess and validate intra-operative placement values for both inclinat...

متن کامل

Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.

BACKGROUND Successful hip reconstruction to restore the normal hip biomechanics requires precise placement of implants. Computer assisted navigation in total hip arthroplasty has been proposed to have the potential to help achieve a high accuracy in implant placement. The goal of the study was to evaluate the accuracy of an imageless computer navigation system on cadavers and to validate a non-...

متن کامل

Initial Results of an Acetabular Center Axis Registration Technique in Navigated Hip Arthroplasty with Deformed Acetabular Rims

BACKGROUND In cementless total hip arthroplasty, imageless computer-assisted navigation is usually used to register the anterior pelvic plane (APP). The accuracy of this method is influenced by the subcutaneous tissues overlying the registration landmarks. On the other hand, the acetabular center axis (ACA) is determined from the acetabular rim. Precise registration of the ACA is possible becau...

متن کامل

Evaluation of an Ultrasound Approach to Overcome Soft-tissue Interference on Digitizing Bony Landmarks in Navigation Assisted Total Hip Arthroplasty (tha)

INTRODUCTION: An imageless Computer-Assisted Navigation System (NAV) in THA has been shown to help increase the accuracy of cup placement [1-2]. NAV relies on the location of the Anterior Superior Iliac Spines (ASISs) and the Pubic Symphysis (PS) to establish the pelvic coordinate system for operation. However, in obese individuals, who account for more than half of the patient population, palp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 35 10 Suppl  شماره 

صفحات  -

تاریخ انتشار 2012