Real-time complex amplitude reconstruction method for beam quality M2 factor measurement.
نویسندگان
چکیده
We present a real-time complex amplitude reconstruction method for determining the beam propagation ratio M2 of laser beams based on the transport of intensity equation (TIE). In this work, a synchronous acquisition system consisting of two identical CCDs is established. Once two beam intensity images at different cross-section positions along the optical axis are captured simultaneously by the system, the complex amplitude of the laser beam can be rapidly reconstructed using TIE algorithm. Then the beam intensity distribution at any section position along its propagation direction can be obtained by using angular spectrum (AS) theory. The beam quality M2 factor is therefore calculated utilizing the second-order moments and hyperbola fitting methods, which conform to the ISO standard. The suitability of this method is verified by the numerical analysis and experiments with the He-Ne and high-power fiber laser sources, respectively. The experimental technique is simple and fast, which allows to investigate laser beams under conditions inaccessible to other methods.
منابع مشابه
Measurement of M2-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
For asymmetric laser beams, the values of beam quality factor M x 2 and M y 2 are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M²-curve is developed. The M²-curve not only contains the beam quality...
متن کاملFast System Matrix Calculation in CT Iterative Reconstruction
Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...
متن کاملLaser beam complex amplitude measurement by phase diversity.
The control of the optical quality of a laser beam requires a complex amplitude measurement able to deal with strong modulus variations and potentially highly perturbed wavefronts. The method proposed here consists in an extension of phase diversity to complex amplitude measurements that is effective for highly perturbed beams. Named camelot for Complex Amplitude MEasurement by a Likelihood Opt...
متن کاملDevelopment of a Method for Measuring the M2 Parameter of a Laser
The M2 factor has become a popular and important parameter, used to characterize the quality of a laser beam. A procedure for making an accurate M2 measurement of a laser is developed and described. Also discussed are several methods of measurement which did not yield adequate results.
متن کاملLaser beam quality measurement by micro lens array method
In the traditional laser beam quality measurement, the lens transform method is used to obtain the information of the multi spot, and can only evaluate the beam quality of a continuous or high repetition rate laser, the evaluation speed is slow and the real-time performance is poor. A micro lens array method is proposed, which samples the laser spot only once and obtains all the spot informatio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 25 17 شماره
صفحات -
تاریخ انتشار 2017