Thallium-201 for assessment of myocardial viability: quantitative comparison of 24-hour redistribution imaging with imaging after reinjection at rest.

نویسندگان

  • D S Kayden
  • S Sigal
  • R Soufer
  • J Mattera
  • B L Zaret
  • F J Wackers
چکیده

Redistribution thallium-201 imaging 2 to 4 h after exercise may be incomplete and therefore may be inadequate to fully assess myocardial variability. Late redistribution imaging 24 h after exercise has been proposed to overcome this limitation of thallium stress imaging. However, because of poor count density the image quality on these studies is often suboptimal. In the present study the diagnostic information on 24-h planar thallium redistribution images was compared with that on images obtained after a reinjection of thallium at rest. Eighty-four patients with a stress thallium-201 defect had delayed redistribution imaging after 2 to 4 h and 24 h later, and again after an injection of thallium at rest. Defect reversibility on 24-h redistribution images was compared quantitatively with that on images after injection of thallium at rest. The quality of thallium images at rest was consistently better than that of 24-h redistribution images. Poor quality studies occurred in 13% of 24-h redistribution images compared with 0.4% of the studies at rest. Significantly more defect reversibility was detected on images after the reinjection at rest. Of 41 patients who appeared to have a fixed defect at 2- to 4-h redistribution imaging, 11 (27%) had a reversible defect by 24-h redistribution imaging compared with 29 (71%) after thallium-201 reinjection. No clinical variables at the time of stress testing were predictive of late defect reversibility. It is concluded that in patients with fixed a thallium defect at 2 to 4 h after exercise, reimaging after a reinjection at rest provides better diagnostic information than does 24-h late redistribution imaging.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thallium reinjection after stress-redistribution imaging. Does 24-hour delayed imaging after reinjection enhance detection of viable myocardium?

BACKGROUND Thallium reinjection immediately after conventional stress-redistribution imaging improves the detection of viable myocardium, as many myocardial regions with apparently "irreversible" thallium defects on standard 3-4-hour redistribution images manifest enhanced thallium uptake after reinjection. Because the 10-minute period between reinjection and imaging may be too short, the prese...

متن کامل

Does 24-Hour Delayed Imaging After Reinjection Enhance Detection of Viable Myocardium?

Background. Thallium reinjection immediately after conventional stress-redistribution imaging improves the detection of viable myocardium, as many myocardial regions with apparently "irreversible" thallium defects on standard 3-4-hour redistribution images manifest enhanced thallium uptake after reinjection. Because the 10-minute period between reinjection and imaging may be too short, the pres...

متن کامل

Differential Uptake and Apparent 20TI Washout After Thallium Reinjection Options Regarding Early Redistribution Imaging Before Reinjection or Late Redistribution Imaging After Reinjection

Background. Because thallium reinjection enhances the identification of viable myocardium, many laboratories have adopted the routine practice of performing reinjection imaging instead of 3-4-hour redistribution imaging. This approach assumes that the stress-reinjection protocol provides the necessary information regarding both exercise-induced ischemia and myocardial viability. Because apparen...

متن کامل

Differential uptake and apparent 201Tl washout after thallium reinjection. Options regarding early redistribution imaging before reinjection or late redistribution imaging after reinjection.

BACKGROUND Because thallium reinjection enhances the identification of viable myocardium, many laboratories have adopted the routine practice of performing reinjection imaging instead of 3-4-hour redistribution imaging. This approach assumes that the stress-reinjection protocol provides the necessary information regarding both exercise-induced ischemia and myocardial viability. Because apparent...

متن کامل

Stress-Redistribution-Reinjection and Rest-Redistribution Thallium Imaging for Assessing Viable Myocardium Comparison With Metabolic Activity by Positron Emission Tomography

Background. Stress thallium scintigraphy provides important diagnostic and prognostic information in patients with coronary artery disease by demonstrating regional myocardial ischemia. However, if the clinical question being addressed is whether a region is viable and not whether there is inducible ischemia, then it may be more reasonable to perform rest-redistribution imaging rather than stre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 1991