Measurement of dioxins in human blood: improvement of analytical method.

نویسندگان

  • Takao Iida
  • Takashi Todaka
چکیده

We have improved the method of measuring dioxins in the blood of Yusho patients; with this improved method, it is possible to take measurements quickly and precisely, using as little as 5g of blood. The specific points of improvement of this method are the extraction of lipids from blood by accelerated solvent extractor (ASE), the miniaturization of column cleanup for the purification of dioxins, and the use of a solvent cut large volume (SCLV) injection system with high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). Using this improved method of analysis, we are currently investigating dioxins in the blood of 400 Yusho patients collected in Japan in 2002. We here describe the details of our announcement at Dioxin 2002 Symposium about the improvement of this analysis method, and discuss several other modifications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improvement of measurement method for hydroxylated polychlorinated biphenyls (OH-PCBs) in blood samples using LC/MS/MS.

Hydroxylated polychlorinated biphenyls (OH-PCBs) are well known as metabolites of PCBs in the human body. We improved a measurement method for OH-PCBs in blood samples using LC/MS/MS. A new 2 microm particle column was used, and the analytical conditions for the LC/MS/MS measurements were optimized. The improved method is more sensitive than the conventional method for 5g blood samples. And, th...

متن کامل

New protocol of dioxins analysis in human blood.

We developed a new analytical method for accurately determining concentrations of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs) and non-ortho-coplanar polychlorinated biphenyls (Co-PCBs) at a blood volume of 5 g. The method consists of three major steps, the extraction of lipid from human blood by an accelerate solvent extractor (ASE) system, a clean-up proced...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Recent advances in mass spectrometric measurement of dioxins.

Past years, many efforts have been dedicated to the development of alternative analytical methods for the measurement of dioxins in various types of matrices. Polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), and polychlorinated biphenyls (PCBs) are compounds that are present in samples at part-per-billion (ppb) or part-per-trillion (ppt) level. Their measurement...

متن کامل

QSAR Studies of the Dioxins and Interaction of OCDD with Calix[4] Arene Using DFT

Quantum chemical calculations, based on Density Functional Theory (DFT) method, were performed on Calix[4]arene and Polychlorinated Dibenzo-p-dioxins (PCDDs) in gas and liquid phases for comparison purposes. The simulation results show the 1,2,3,4, 6,7,8,9-octachlorodibenzo-p-dioxin (OCDD) is quite a reactive dioxin. This paper attempts to examine the possibility of dioxin adsorption by Calix[n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Industrial health

دوره 41 3  شماره 

صفحات  -

تاریخ انتشار 2003