Results of preliminary clinical trials of the positron emission mammography system PEM-I: a dedicated breast imaging system producing glucose metabolic images using FDG.

نویسندگان

  • K Murthy
  • M Aznar
  • C J Thompson
  • A Loutfi
  • R Lisbona
  • J H Gagnon
چکیده

UNLABELLED Early detection of breast cancer is crucial for efficient and effective treatment. We have developed an instrument for positron emission mammography (PEM) called PEM-I that performs high-resolution metabolic imaging of breast cancer. Images of glucose metabolism are obtained after injection of 75 MBq FDG. The PEM detectors are integrated into a conventional mammography system, allowing acquisition of the emission images immediately after the mammogram, without subject repositioning, and accurate coregistration of images from the 2 modalities. In this article, we present the results of the first clinical pilot study with the instrument. METHODS Sixteen subjects (age range, 34-76 y) were studied. All subjects were nondiabetic, nonpregnant, and without a history of cancer. They had recently been found to have suggestive mammography findings or a palpable breast mass and underwent lumpectomy or mastectomy within 2 wk of the study. Results from the PEM study were compared with those from mammography and pathology. A PEM test was classified positive (indicating the presence of cancer) if significant focal uptake was seen in the image or if the counting rate in the breast with suggestive findings was significantly higher than in the contralateral breast. RESULTS Of the 16 subjects studied, 14 were evaluable. Ten cancerous tumors and 4 benign tumors were confirmed by pathologic examination after complete removal of the tumor. PEM correctly detected the presence of disease in 8 of 10 subjects. Findings were false-negative in 2 instances and false-positive in none, giving the instrument 80% sensitivity, 100% specificity, and 86% accuracy. CONCLUSION Our preliminary results suggest that PEM can offer a noninvasive method for the diagnosis of breast cancer. Metabolic images from PEM contain unique information not available from conventional morphologic imaging techniques and aid in expeditiously establishing the diagnosis of cancer. In all subjects, the PEM images were of diagnostic quality, with an imaging time of 2-5 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecular imaging approaches in the diagnosis of breast cancer: A systematic review and meta-analysis

Introduction:The accuracy of positron emission tomography with computed tomography (PET/CT), positron emission mammography (PEM), and breast specific-gamma imaging (BSGI) in diagnosing breast cancer has never been systematically assessed, the present systematic review was aimed to address this issue.  Methods:PubMed, Scopus and EMBASE were searched for st...

متن کامل

Software Tools for Breast Cancer Detection in Positron Emission Mammography Images

Positron Emission Mammography (PEM) is a novel imaging technology utilizing a dedicated Positron Emission Breast scanner. Two detectors in a configuration that resembles a conventional mammography (MG) machine cover a 250x120x200 mm3 volume, yielding 3D images of the breast, which is fixated between the detectors, but not compressed. The procedure depends on the administration of a radioactive ...

متن کامل

Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...

متن کامل

PEM or MBI?

We have read with utmost interest the preliminary report by Yamamoto et al. of breast cancer screening by fluorine18 fluorodeoxyglucose (F-FDG) positron emission mammography (PEM) [1]. However, despite its many reported advantages, we have some concerns about its actual superiority in the diagnosis of tumours in the dense breast tissue. At present, there also reports on the application of anoth...

متن کامل

Technique to obtain positron emission mammography images in registration with x-ray mammograms.

X-ray mammograms reveal abnormal tissue densities, while metabolic images identify regions of abnormal metabolism. Conventional nuclear medicine and radiologic breast images must be acquired at different times with different patient positions making coregistration difficult. Accurate coregistration of metabolic and x-ray images of the breast is likely to be important when acquiring information ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 41 11  شماره 

صفحات  -

تاریخ انتشار 2000