Measurement of lumbar multifidus muscle contraction with rehabilitative ultrasound imaging.

نویسندگان

  • Kyle B Kiesel
  • Tim L Uhl
  • Frank B Underwood
  • Donald W Rodd
  • Arthur J Nitz
چکیده

Rehabilitative Ultrasound Imaging (RUSI) has been validated as a noninvasive method to measure activation of selected muscles. The purpose of this study was to determine the relationship between muscle thickness change, as measured by ultrasonography, and electromyography (EMG) activity of the lumbar multifidus (LM) muscle in normal subjects. Bipolar fine wire electrodes were inserted into the LM at the L4 level of five subjects. Simultaneous EMG and RUSI data (muscle thickness) were collected while subjects performed increasingly demanding postural response tasks thought to activate the LM muscle. To determine the relationship between muscle thickness change and EMG activity, the normalized EMG data were correlated to normalized RUSI data. To determine if the tasks increased the demand on the LM, the mean EMG data were compared over each of the four tasks. Muscle thickness change as measured by RUSI was highly correlated with EMG activity of LM in asymptomatic subjects (r=.79,P<.001). Mean EMG data showed increasing levels of activation across tasks (19-34% of maximum voluntary isometric contraction (MVIC)). The results of the repeated measures ANOVA demonstrated theses differences were significant (F(3,12)=25.39,P<.001). Measurement of muscle thickness change utilizing RUSI is a valid and potentially useful method to measure activation of the LM muscle in a narrow range (19-34% of MVIC) in an asymptomatic population.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved activation of lumbar multifidus following spinal manipulation: a case report applying rehabilitative ultrasound imaging.

STUDY DESIGN Case report. BACKGROUND The use of spinal manipulation as a treatment to facilitate neuromuscular control of the paraspinal musculature is not well described in the literature. The use of rehabilitative ultrasound imaging (RUSI) may offer a convenient way to investigate and document possible changes occurring in the lumbar multifidus associated with manipulation intervention. C...

متن کامل

The Reliability of Rehabilitative Ultrasound Imaging of the Cross-sectional Area of the Lumbar Multifidus Muscles in the PNF Pattern

[Purpose] The primary purpose of this study was to evaluate the intraclass correlation coefficient (ICC) in obtaining the cross-sectional area of the lumbar multifidus muscles in patients with chronic low back pain (LBP) at rest and during contractions facilitated by PNF patterns by ultrasound imaging. [Subjects] The subjects were 15 (4 males, 11 females) who had chronic LBP on one side for mor...

متن کامل

Reliability of 2 ultrasonic imaging analysis methods in quantifying lumbar multifidus thickness.

STUDY DESIGN Reliability study. OBJECTIVES To compare the within- and between-day intrarater reliability of rehabilitative ultrasound imaging (RUSI) using static images (static RUSI) and video clips (video RUSI) to quantify multifidus muscle thickness at rest and while contracted. Secondary objectives were to compare the measurement precision of averaging multiple measures and to estimate rel...

متن کامل

The effect of chronic low back pain on size and contraction of the lumbar multifidus muscle.

Decreases in the size of the multifidus muscle have been consistently documented in people with low back pain. Recently, ultrasound imaging techniques have been used to measure contraction size of the multifidus muscle, via comparison of the thickness of the muscle at rest and on contraction. The aim of this study was to compare both the size (cross-sectional area, CSA) and the ability to volun...

متن کامل

The effect of averaging multiple trials on measurement error during ultrasound imaging of transversus abdominis and lumbar multifidus muscles in individuals with low back pain.

STUDY DESIGN Clinical measurement, reliability study. OBJECTIVES To investigate the improvements in precision when averaging multiple measurements of percent change in muscle thickness of the transversus abdominis (TrA) and lumbar multifidus (LM) muscles. BACKGROUND Although the reliability of TrA and LM muscle thickness measurements using rehabilitative ultrasound imaging (RUSI) is good, m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Manual therapy

دوره 12 2  شماره 

صفحات  -

تاریخ انتشار 2007