Spot size and quality of scanning laser correction of higher order wavefront aberrations.

نویسندگان

  • D Huang
  • M Arif
چکیده

PURPOSE To investigate the effect of laser spot size on the outcome of aberration correction with scanning laser corneal ablation. METHODS Numerical simulation of ablation outcome. RESULTS Correction of wavefront aberrations of Zernike modes from second to eighth order were simulated. Gaussian and top-hat beams of 0.6 to 2.0-mm full-width-half-maximum diameters were modeled. The fractional correction and secondary aberration (distortion) were evaluated. Using a distortion/correction ratio of less than 0.5 as a cutoff for adequate performance, we found that a 2 mm or smaller beam is adequate for spherocylindrical correction (Zernike second order), a 1 mm or smaller beam is adequate for correction of up to fourth order Zernike modes, and a 0.6 mm or smaller beam is adequate for correction of up to sixth order Zernike modes. CONCLUSIONS Since ocular aberrations above Zernike fourth order are relatively insignificant, current scanning lasers with a beam diameter of 1 mm or less are theoretically capable of eliminating most of the higher order aberrations of the eye.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Technology requirements for Summit-Autonomous CustomCornea.

W ith the recent surge of interest in wave-front sensing technology as a new diagnostic tool in refractive surgery 1,2 , the concept of wavefront customized correction has now come to the forefront. 3,4 Among the companies leading this effort, the Summit-Autonomous Technologies provides a technology platform within CustomCornea which can be used as a model for wavefront ablation requirements. A...

متن کامل

Comparison of 2 wavefront-guided excimer lasers for myopic laser in situ keratomileusis: one-year results.

PURPOSE To compare laser in situ keratomileusis (LASIK) outcomes between 2 wavefront-guided excimer laser systems in the treatment of myopia. SETTING University eye clinic, Palo Alto, California, USA. DESIGN Prospective comparative case series. METHODS One eye of patients was treated with the Allegretto Wave Eye-Q system (small-spot scanning laser) and the fellow eye with the Visx Star Cu...

متن کامل

Optimization of the dynamic wavefront control of a pulsed kilojoule/nanosecond-petawatt laser facility.

The wavefront aberrations in a large-scale, flash-lamp-pumped, high-energy, high-power glass laser system can degrade considerably the quality of the final focal spot, and limit severely the repetition rate. The various aberrations induced on the Laboratoire pour l'Utilisation des Lasers Intenses (LULI), laser facility (LULI2000) throughout the amplification are identified and analyzed in detai...

متن کامل

Wavefront-guided laser in situ keratomileusis: early results in three eyes.

PURPOSE Wavefront optical aberrations induced by refractive corneal surgery correction of myopia are probably the reason for deterioration of visual performance in some eyes after surgery. Customized photoablation of the cornea to correct both the sphero-cylindrical refractive error as well as individual optical aberrations may improve postoperative visual acuity and visual performance. METHO...

متن کامل

Refractive Surgery Feature Story

SEPTEMBER 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 35 T he introduction of wavefront-sensing techniques to ophthalmology has redefined the clinical meaning of refractive error. Now, all imperfections in the components and materials within the eye that cause light rays to deviate from their desired path are referred to as optical aberrations. Lower-order aberrations (defocus and astigmati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 17 5  شماره 

صفحات  -

تاریخ انتشار 2001