Comparison of the technical and clinical performance of the Elecsys HBsAg II assay with the Architect, AxSym, and Advia Centaur HBsAg screening assays.
نویسندگان
چکیده
South East Asia has some of the highest prevalence rates of hepatitis B virus (HBV) infection (>or=8%) in the world, and the emergence of hepatitis B surface antigen (HBsAg) mutant strains is a growing problem. Assays with the highest levels of sensitivity, including mutant detection, should be used for routine HBsAg screening. In this large multicenter study, the clinical and technical performance of the fully automated Elecsys HBsAg II assay was compared with the Architect, AxSYM, and Advia Centaur HBsAg assays for HBsAg screening. Nine laboratories (three each from Thailand, Korea, and Singapore) compared the Elecsys HBsAg II assay with their routine HBsAg screening assay against a range of stored and routine clinical samples, including recombinant mutants. The Elecsys HBsAg II assay demonstrated equivalent sensitivity and specificity to the Architect HBsAg assay. However, the Elecsys HBsAg II assay recognized a native mutant sample (L94S, L97V, L98V, T123A) that the Architect HBsAg assay failed to detect. The AxSYM and Advia Centaur HBsAg assays appeared less sensitive for the detection of early HBV infection and also failed to detect some of the recombinant mutant strains. There was almost complete agreement between the Elecsys HBsAg II assay and comparator assays with respect to routine serum samples. The results of this study demonstrate that the Elecsys HBsAg II assay is a highly sensitive and specific screening assay for HBsAg and detects reliably the most important and clinically relevant HBV mutants and genotypes. It is suitable for routine HBsAg screening in Asia.
منابع مشابه
[Comparison of three assay systems for qualitative and quantitative results of hepatitis B surface antibody.].
BACKGROUND With a technical improvement of the assay system, automated immunoassay analyzers for hepatitis B surface antibody (anti-HBs) are widely used. However, some discrepancies between assays are still being reported. We compared the qualitative and quantitative results of three kinds of anti-HBs assays. METHODS Serum samples were collected from 517 patients and anti-HBs were determined ...
متن کاملComparison of the Elecsys HBsAg II Assay and the Architect Assay for Quantification of hepatitis B surface antigen in patients with chronic hepatitis B.
Quantitative hepatitis B surface antigen (HBsAg) is a valuable tool in hepatitis B virus (HBV) disease diagnosis and management for evaluating the effectiveness of antiviral therapy. The aim of the current research was to compare the performances of the Elecsys HBsAg II and Abbott Architect HBsAg assays in chronic hepatitis B (CHB) patients. Between May 2014 and December 2014, 72 CHBs were test...
متن کاملSensitivities of four new commercial hepatitis B virus surface antigen (HBsAg) assays in detection of HBsAg mutant forms.
Mutations in hepatitis B virus surface antigen (HBsAg) involving amino acid substitution within the immunodominant "a" determinant may affect the performance of commercial HBsAg assays. The performances of four HBsAg assays that recently received Conformité Européene marking, Advia Centaur HBsAg (Bayer), Monolisa HBsAg Ultra (Bio-Rad), Liaison HBsAg (Dia Sorin), and Vidas HBsAg Ultra (bioMérieu...
متن کاملPerformance characteristics of eight estradiol immunoassays.
Measurement of estradiol is useful in assisted reproduction, evaluation of infertility, menopause, and male feminization. The analytic performance of 8 estradiol immunoassays was evaluated. The imprecision and accuracy of the Access, ADVIA Centaur, ARCHITECT i2000, AutoDELFIA, Elecsys 2010, IMMULITE 2000, and Vitros ECi estradiol assays (see text for proprietary information) were evaluated by u...
متن کاملComparison of 3 Automated Immunoassays for Detection of Anti-Hepatitis A Virus Immunoglobulin M in a Tertiary Care Hospital
Three automated immunoassay kits for anti-Hepatitis A Virus (HAV) IgM-Architect, (Abbott Laboratories, USA), Elecsys (Roche Diagnostics, Germany), and ADVIA Centaur (Siemens Healthcare Diagnostics Inc., USA)-were compared. We included 178 consecutive samples, for which an anti-HAV IgM test was requested at Seoul National University Hospital from September 2009 to January 2010. Reviewing of medi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of medical virology
دوره 82 5 شماره
صفحات -
تاریخ انتشار 2010