P ractical approaches to fast gas chromatography – mass q spectrometry * ˇ ˇ ́
نویسندگان
چکیده
Fast gas chromatography–mass spectrometry (GC–MS) has the potential to be a powerful tool in routine analytical laboratories by increasing sample throughput and improving laboratory efficiency. However, this potential has rarely been met in practice because other laboratory operations and sample preparation typically limit sample throughput, not the GC–MS analysis. The intent of this article is to critically review current approaches to fast analysis using GC–MS and to discuss practical considerations in addressing their advantages and disadvantages to meet particular application needs. The practical ways to speed the analytical process in GC and MS individually and in combination are presented, and the trade-offs and compromises in terms of sensitivity and/or selectivity are discussed. Also, the five main current approaches to fast GC–MS are described, which involve the use of: (1) short, microbore capillary GC columns; (2) fast temperature programming; (3) low-pressure GC–MS; (4) supersonic molecular beam for MS at high GC carrier gas flow; and (5) pressure-tunable GC–GC. Aspects of the different fast GC–MS approaches can be combined in some cases, and different mass analyzers may be used depending on the analytical needs. Thus, the capabilities and costs of quadrupole, ion trap, time-of-flight, and magnetic sector instruments are discussed with emphasis placed on speed. Furthermore, applications of fast GC–MS that appear in the literature are compiled and reviewed. At this time, the future usefulness of fast GC–MS depends to some extent upon improvement of existing approaches and commercialization of interesting new techniques, but moreover, a greater emphasis is needed to streamline overall laboratory operations and sample preparation procedures if fast GC–MS is to become implemented in routine applications. Published by Elsevier Science B.V.
منابع مشابه
Impact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study
In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method sh...
متن کاملImpact of Pharmaceutical Impurities in Ecstasy Tablets: Gas Chromatography-Mass Spectrometry Study
In this study, a simple and reliable method by gas chromatograph–mass spectrometry (GC–MS) was developed for the fast and regular identification of 3, 4-MDMA impurities in ecstasy tablets. In so doing, 8 samples of impurities were extracted by diethyl ether under alkaline condition and then analyzed by GC–MS. The results revealed high MDMA levels ranging from 37.6% to 57.7%. The GC-MS method sh...
متن کاملOn R L Cohen’s –element
Let p be a prime greater than three. In the p–local stable homotopy groups of spheres, R L Cohen constructed the infinite –element n 1 2 2pnC1 2pnC2p 5.S/ of order p . In the stable homotopy group 2pnC1 2pnC2p2 3.V .1// of the Smith– Toda spectrum V .1/ , X Liu constructed an essential element $k for k 3 . Let ˇ s D j0j1ˇ s 2 ŒV .1/;S 2sp2 2s 2p denote the Spanier–Whitehead dual of the generat...
متن کاملA class function on the mapping class group of an orientable surface and the Meyer cocycle
Meyer [9] defined a cocycle g 2Z.MgIZ/ (g 0) called the Meyer cocycle which represents four times generator of the second cohomology class when g 3. Let D1 , D2 , and D3 be mutually disjoint disks in S , and Int Di the interior of Di for i D 1; 2; 3. We denote by P WDS q iD1 Int Di the pair of pants, and ̨; ˇ; 2 1.P / be the homotopy classes as shown in Figure 1. We consider a †g;r –bundle E '; ...
متن کاملT lymphocytes to chemokines
Two subpopulations of human T lymphocytes expressing different antigen receptors, § / g and + / ˇ , emigrate into inflamed tissues in distinctive patterns. We compared the transmigration of § / g and + / ˇ T cells to C-C and C-X-C chemokines using an in vitro transendothelial chemotaxis assay. The C-C chemokines monocyte chemoattractant protein (MCP)-1, RANTES, macrophage inflammatory protein (...
متن کامل