The efficacy of a two needle electrode technique in percutaneous radiofrequency rhizotomy:An investigational laboratory study in an animal model.
نویسندگان
چکیده
BACKGROUND Radiofrequency neurotomies are used to help reduce pain caused by structures innervated by the medial branch of the dorsal spinal nerve. The duration of effect may vary proportionally to the length of nerve coagulated. Techniques used to maximize the length of nerve within the radius of maximal heat include making multiple lesions, using larger needles, positioning the exposed needle parallel to the target nerve, and attempting more precise placement using 50 hertz test stimulation. A variation of the technique uses two needles that are simultaneously placed to lie parallel to one another and parallel to the probable area the target nerve is known to traverse. Heating both needles at the same time would be a faster method that theoretically might also include more tissue within the heating radius of the needle lengths. OBJECTIVE The purpose of this study was to confirm that two parallel radiofrequency lesions increased the volume of tissue included within the heating radius of the exposed needle tips, to determine optimal heating parameters, and to establish how far apart the needles can be placed and still achieve temperatures between the needles that will coagulate nerves. STUDY DESIGN Investigational laboratory study in an animal model. METHODS Ex-vivo porcine spinal tissue samples were prepared following a standardized protocol and two needle electrodes were connected to the Stryker rhizotomy device. A series of tissue samples were prepared with the needles placed 1, 1.5, 2, 3, 4, 5, 6, 7, 8, or 9 mm apart in respective samples. The needles were positioned parallel to the surface, and perpendicular to the tissue. In one series of samples, two needle electrodes were heated sequentially for each needle placement. Temperature parameters ranged from 60 to 100 degrees C and the time duration ranged from 60 to 90 seconds for each electrode. After each heating, all tissue was dissected and the size of the coagulated area measured. Temperatures at the midpoint between the two needle electrodes were monitored and measured with a Radionics needle sensor. Using the same study protocol and evaluation, a second set of samples was studied but both needle electrodes were heated simultaneously. RESULTS Maximal lesion size was observed when the temperature of the electrode was higher than 70-80 degrees C and maintained for longer than 70 seconds. When the needles were heated sequentially, the needles could be placed no further than 1.5 to 2 mm apart before areas of incomplete coagulation were visualized at the midpoint between the needles. When both needles were simultaneously heated the needles could be placed 4 mm apart before incomplete coagulation was visualized. With simultaneous heating, the highest peak temperature of the midpoint between two needles (6 mm apart) exceeded 66 degrees C, compared to a temperature of 40 degrees C achieved with sequential heating. CONCLUSIONS This research confirms the efficacy of utilizing two needle electrodes during lumbar facet rhizotomy in an experimental model. Heating the two electrodes sequentially appears to coagulate a wider area and thus would be more likely to include a longer length of the target nerve and thus potentially could achieve better results in less time.
منابع مشابه
Survey of the Effects of Exposure to 900 MHz Radiofrequency Radiation Emitted by a GSM Mobile Phone on the Pattern of Muscle Contractions in an Animal Model
Introduction: The rapid development of wireless telecommunication technologies over the past decades, has led to significant changes in the exposure of the general public to electromagnetic fields. Nowadays, people are continuously exposed to different sources of electromagnetic fields such as mobile phones, mobile base stations, cordless phones, Wi-Fi routers, and power lines. Therefore, th...
متن کاملA study on striatal local electrical potential changes in an animal model of Parkinson's disease
Parkinson’s disease (PD) is a neurodegenerative disorder that does not develop spontaneously in some animal species. PD can be induced experimentally in some laboratory animals including mouse, rat and horse. Globus pallidus (GP) and substantia nigra pars compacta (SNc) are damaged in patients with PD. The hallmark of PD is a progressive impaired control of movement, an alteration of autonomic ...
متن کاملA study on striatal local electrical potential changes in an animal model of Parkinson's disease
Parkinson’s disease (PD) is a neurodegenerative disorder that does not develop spontaneously in some animal species. PD can be induced experimentally in some laboratory animals including mouse, rat and horse. Globus pallidus (GP) and substantia nigra pars compacta (SNc) are damaged in patients with PD. The hallmark of PD is a progressive impaired control of movement, an alteration of autonomic ...
متن کاملExposure to Radiofrequency Radiation Emitted from Common Mobile Phone Jammers Alters the Pattern of Muscle Contractions: an Animal Model Study
Introduction: The fast-growing telecommunication and wireless technologies has led to more dependence to these communication devices and higher levels of exposure to electromagnetic radiations propagated by cellular devices and their service towers. To disable signaling in places where silence is valued or where information quarantine measures are required, mobile phone jammers emit radiofreque...
متن کاملPercutaneous Radiofrequency Ablation of Renal Cell Carcinoma
Background: Preliminary data regarding the use of percutaneous radiofrequency ablation (RFA) for the treatment of renal cell carcinoma (RCC) are encouraging, and show the technique to be associated with minimal morbidity. Thus, the current study was designed to evaluate the clinical applications, treatment efficacy, and complications of percutaneous RFA in RCC. Methods: From February 2003 to Fe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Pain physician
دوره 9 3 شماره
صفحات -
تاریخ انتشار 2006