Postoperative Corneal and Surgically Induced Astigmatism following Superior Approach Manual Small Incision Cataract Surgery in Patients with Preoperative Against-the-Rule Astigmatism

نویسندگان

  • Edmund Arthur
  • Ahmed Abdul Sadik
  • David Ben Kumah
  • Eugene Appenteng Osae
  • Felix Agyemang Mireku
  • Frank Yeboah Asiedu
  • Reynolds Kwame Ablordeppey
چکیده

The aim of the study was to report postoperative corneal and surgically induced astigmatism (SIA) in patients with preoperative against-the-rule (ATR) astigmatism who underwent superior approach manual small incision cataract surgery (MSICS). 58 eyes of 58 cataract patients with preoperative ATR astigmatism were involved in this study. All patients had operable cataracts and underwent superior approach MSICS. Keratometric (K) readings were taken prior to surgery and at 12 weeks after surgery. Centroid values of SIA, preoperative astigmatism, and postoperative astigmatism were calculated using Cartesian coordinates based analysis. Wilcoxon signed rank test was used to compute statistical significance between mean preoperative and postoperative corneal astigmatism. Cohen's d was used as effect size measure. Centroid values of 1.42 D × 179, 2.48 D × 0, and 1.07 D × 1 were recorded, respectively, for preoperative astigmatism, postoperative astigmatism, and SIA. Wilcoxon signed rank test indicated that mean ± SD postoperative corneal astigmatism (2.80 ± 1.40 D) was statistically significantly greater than preoperative corneal astigmatism (1.49 ± 1.34 D), Z = -6.263, p < 0.0001. A high Cohen's d of 1.32 was found. Our results suggest statistical and clinically significant greater postoperative corneal astigmatism than preoperative corneal astigmatism for ATR astigmatism cataract patients who underwent superior approach MSICS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Astigmatism following cataract surgery.

The changes in corneal curvature were determined at regular intervals over a one-year period following intracapsular cataract extraction by microsurgical techniques. During the first postoperative month photokeratometric measurements showed rapid changes in astigmatism associated with large changes in the direction of the axis. Thereafter astigmatism against-the-rule predominated. Data from the...

متن کامل

Minimizing Surgically Induced Astigmatism at the Time of Cataract Surgery Using a Square Posterior Limbal Incision

Purpose. To compare the surgically induced astigmatism from clear corneal and square posterior limbal incisions at the time of cataract surgery. Methods. Surgically induced astigmatism was calculated for a set of eyes after cataract surgery using a temporal 2.2 mm square posterior limbal incision. Results were compared to similar available data from surgeons using clear corneal incisions of sim...

متن کامل

Effects of preoperative corneal astigmatism orientation on results with a low-cylinder-power toric intraocular lens.

PURPOSE To evaluate refractive results with a low-cylinder-power toric intraocular lens (IOL) and the effect of preoperative corneal astigmatism orientation on results. SETTING Private practice, Jackson, Michigan, USA. DESIGN Comparative case series. METHODS This retrospective review of clinical records comprised patients with 0.75 to 1.38 diopters (D) of preoperative corneal astigmatism ...

متن کامل

A comparative study of sclero-corneal and clear corneal tunnel incision in manual small-incision cataract surgery.

BACKGROUND Cataract surgery techniques have improved a lot over the years from couching to the latest micro-incision cataract surgery. OBJECTIVES To compare the temporal sclero-corneal and clear corneal tunnel incisions in patients undergoing manual small-incision cataract surgery (SICS) with respect to the surgically-induced astigmatism. MATERIALS AND METHODS The present study included 60 ...

متن کامل

Surgically induced corneal refractive change following glaucoma surgery: nonpenetrating trabecular surgeries versus trabeculectomy.

PURPOSE To compare surgically induced corneal refractive change following trabeculectomy with the nonpenetrating trabecular filtering surgeries with and without implant. SETTING Department of Ophthalmology, Ege University School of Medicine, Izmir, Turkey. METHODS A consecutive series of 34 patients (34 eyes) with uncontrolled open-angle glaucoma had trabecular filtering surgery. Patients w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016