Impact of mini-implant length on stability at the initial healing period: a controlled clinical study

نویسندگان

  • Manuel Nienkemper
  • Benedict Wilmes
  • Alexander Pauls
  • Dieter Drescher
چکیده

INTRODUCTION Aim of the study was to assess the impact of the length of mini-implants inserted in the midpalatal region on the stability at the initial healing period. METHODS A sample of 20 consecutively treated patients (15.6 ± 7.2 years) was examined. A long mini-implant with a length of 11 mm and a diameter of 2 mm was inserted into the anterior palate of each patient. Resonance frequency analysis (RFA) was performed after insertion (T0), two weeks (T1), four weeks (T2), and six weeks (T3). Insertion depth (ID) and the maximum insertion torque (IT) were measured. RFA, ID and IT data were tested for correlations. RFA values were tested for statistical differences between the different times. Data was compared to a matched control group of patients who received short mini-implants with a length of 9 mm and a diameter of 2 mm. RESULTS Mean ID was 9.5 ± 0.6 mm and mean IT was 17.9 ± 3.8 Ncm. A correlation was found between RFA and ID (r = 0.59, P < .01). From T0 to T1 the stability (33.4 ± 3.5 ISQ) decreased highly significantly by 5.3 ± 3.5 ISQ values (P < .001) and significantly from T1 and T2 (P < .05) by 3.5 ± 3.7 ISQ values. From T2 on RFA nearly remained unchanged (-1.7 ± 3.9 ISQ; P > .05). At T1 stability was significantly lower than the control group. From T2 on there were no significant differences between the groups. CONCLUSIONS Long mini-implants provide high stability when inserted in the midpalatal region. After initial decrease RFA values remained stable from four weeks on and did not differ from the control group. TRIAL REGISTRATION ID 2013081293 (Clinical study register, University of Düsseldorf, Germany).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impact of mini trampoline exercise on dynamic balance in old women

Introduction: An increase of age may cause an obvious effect on physiologic systems which are involved in the balance function. It is estimated that 6% of health care costs are spent on unintentional injuries in elderly population. The aim of this study is to analyze the effect of Mini-trampoline training on dynamic balance abilities in the elderly subjects. Methods: During a clinical tri...

متن کامل

Effect of mini-implant length and diameter on primary stability under loading with two force levels.

Mini-implants are widely utilized as anchorage units in orthodontic treatment. Nevertheless, there are factors that interfere with their clinical performance. The aim of this study was to examine the impact of length and diameter on the primary stability of two different types of orthodontic mini-implants loaded with two force levels. A total of 90 self-drilling mini-implants were inserted in b...

متن کامل

A healing period increases mini-implant stability in growing rats.

We assessed the stability of orthodontic mini-implants in young rats. Male rats with mean ages of 6 weeks (n = 16) and 20 weeks (n = 16) were divided into four groups (n = 8 each). In the 6- and 20-week immediate-loading groups, immediately after placement, mini-implants were exposed to an experimental traction force for 2 weeks. In the 6- and 20-week healing groups, the force was applied for 2...

متن کامل

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

PURPOSE The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess i...

متن کامل

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study

The clinical effectiveness of screw type Implant “Nisastan system” in the posterior region of the mandible: A 2 year prospective study Dr. M. Rismanchian * - Dr. R. Birang ** * Assistant Professor of Fixed Prosthodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences. ** Assistant Professor of Periodontics Dept., Faculty of Dentistry, Isfahan University of Medical Sciences....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2013