Alterations of the Danger Zone after Preparation of Curved Root Canals Using WaveOne with Reverse Rotation or Reciprocation Movements
نویسندگان
چکیده
INTRODUCTION The aim of this study was to compare the changes that occur in the danger zone (DZ) after preparation of curved mesiobuccal (MB) canals of mandibular first molars with WaveOne instruments in two different movements [reciprocation (RCP) and counter-clockwise rotation (CCWR)] by means of cone-beam computed tomography (CBCT). METHODS AND MATERIALS MB canals of 30 mandibular molars were randomly divided into 2 groups (n=15); WaveOne/RCP and WaveOne/CCWR. Pre- and post-instrumentation CBCT images were assessed for changes in the dentin thickness in DZ (2 and 4 mm below the highest point of the root furcation) in both groups. Data was analyzed using the repeated measures ANOVA test. RESULTS There was no statistically significant difference between two experimental groups in terms of remaining dentin thickness at 2 and 4 mm levels below the highest point of the furcation (P>0.05). CONCLUSION The efficacy of WaveOne instrument on changes of the dentin thickness in the DZ was not affected by different file movements.
منابع مشابه
The effect of root canal preparation on the surface roughness of WaveOne and WaveOne Gold files: atomic force microscopy study
Objectives To examine the surface topography of intact WaveOne (WO; Dentsply Sirona Endodontics) and WaveOne Gold (WOG; Dentsply Sirona Endodontics) nickel-titanium rotary files and to evaluate the presence of alterations to the surface topography after root canal preparations of severely curved root canals in molar teeth. Materials and Methods Forty-eight severely curved canals of extracted ...
متن کاملComparison of Canal Transportation and Centering Ability of Wave One and SafeSider in Curved Root Canals Using Cone-Beam Computed Tomography
Background and Aim: Maintaining the original central canal path during cleaning and shaping of the root canal system plays an important role in the success of endodontic treatment. This study sought to compare canal transportation and centering ability of WaveOne and SafeSider rotary files using cone-beam computed tomography (CBCT). Materials and Methods: This in-vitro, experimental study was ...
متن کاملIn vitro Comparison of Apical Debris Extrusion Using Rotary and Reciprocating Systems in Severely Curved Root Canals
INTRODUCTION The aim of this in vitro study was to compare the amount of apically extruded debris after root canal preparation using rotary and reciprocating systems in severely curved root canals. METHODS AND MATERIALS Thirty six extracted human mandibular first molars with 25-35° curvature in their mesiobuccal (MB) canal (according to Schneider's method) were cleaned and shaped with ProTape...
متن کاملComparison of the Shaping Ability of WaveOne Reciprocating Files with or without Glide Path in Simulated Curved S-shaped Root Canals
OBJECTIVES The aim was to compare the shaping ability of WaveOne reciprocating files with or without glide path in simulated curved S-shaped root canals. MATERIALS AND METHODS Forty ISO #15, 0.02 taper, clear resin Endo Training Bloc-S blocks were studied. The simulated curved S-shaped canals were dyed using ink, preinstrumentation images were scanned, and resin blocks were prepared and divid...
متن کاملComparison of WaveOne and ProTaper Universal Preparation Systems in the Amount of Smear Layer/Debris Production: an in-vitro SEM Study
Background and Aim: Debris and the smear layer that remain after root canal preparations may result in failure of root canal therapies. The aim of this study was to compare the smear layer formation and the amount of residual debris following the use of WaveOne and ProTaper rotary files in mesiobuccal root canals of upper first molars by scanning electron microscopy (SEM). Materials and Method...
متن کامل