Single shot whole brain imaging using spherical stack of spirals trajectories
نویسندگان
چکیده
MR-encephalography allows the observation of functional signal in the brain at a frequency of 10 Hz, permitting filtering of physiological "noise" and the detection of single event activations. High temporal resolution is achieved by the use of undersampled non-Cartesian trajectories, parallel imaging and regularized image reconstruction. MR-encephalography is based on 3D-encoding, allowing undersampling in two dimensions and providing advantages in terms of signal to noise ratio. Long readout times, which are necessary for single shot whole brain imaging (up to 75 ms), cause off-resonance artifacts. To meet this issue, a spherical stack of spirals trajectory is proposed in this work. By examining the trajectories in local k-space, it is shown that in areas of strong susceptibility gradients spatial information is fundamentally lost, making a meaningful image reconstruction impossible in the affected areas. It is shown that the loss of spatial information is reduced when using a stack of spirals trajectory compared to concentric shells.
منابع مشابه
Whole-brain background-suppressed pCASL MRI with 1D-accelerated 3D RARE Stack-Of-Spirals readout
Arterial Spin Labeled (ASL) perfusion MRI enables non-invasive, quantitative measurements of tissue perfusion, and has a broad range of applications including brain functional imaging. However, ASL suffers from low signal-to-noise ratio (SNR), limiting image resolution. Acquisitions using 3D readouts are optimal for background-suppression of static signals, but can be SAR intensive and typicall...
متن کاملMagnetization-Prepared Shells With Integrated RadiaL and Spirals
Introduction 3D magnetization-prepared fast gradient echo MR sequences, such as MP-RAGE [1], have been widely used for 3D brain volumetric imaging due to high spatial resolution and good contrast between white matter and gray matter. However, these techniques usually require long acquisition time, which increases the probability of motion and decreases clinical throughput. There have been sever...
متن کاملFast and tissue-optimized mapping of magnetic susceptibility and T2* with multi-echo and multi-shot spirals
Gradient-echo MRI of resonance-frequency shift and T2* values exhibit unique tissue contrast and offer relevant physiological information. However, acquiring 3D-phase images and T2* maps with the standard spoiled gradient echo (SPGR) sequence is lengthy for routine imaging at high-spatial resolution and whole-brain coverage. In addition, with the standard SPGR sequence, optimal signal-to-noise ...
متن کاملComparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملStack-of-Spirals CAIPIRINHA Trajectory for Rapid Volumetric Imaging
Target Audience: MRI physicists and engineers. Purpose: The stack-of-spirals trajectory has been shown to be a very time efficient method to traverse a volumetric k-space for high-resolution imaging (1). Rapid volumetric imaging is useful for high-resolution fMRI at high magnetic fields (2). The long scan times needed for high resolutions however can compromise the temporal resolution of the BO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 73 شماره
صفحات -
تاریخ انتشار 2013