Use of a Modified Vector Model for Odor Intensity Prediction of Odorant Mixtures
نویسندگان
چکیده
Odor intensity (OI) indicates the perceived intensity of an odor by the human nose, and it is usually rated by specialized assessors. In order to avoid restrictions on assessor participation in OI evaluations, the Vector Model which calculates the OI of a mixture as the vector sum of its unmixed components' odor intensities was modified. Based on a detected linear relation between the OI and the logarithm of odor activity value (OAV-a ratio between chemical concentration and odor threshold) of individual odorants, OI of the unmixed component was replaced with its corresponding logarithm of OAV. The interaction coefficient (cosα) which represented the degree of interaction between two constituents was also measured in a simplified way. Through a series of odor intensity matching tests for binary, ternary and quaternary odor mixtures, the modified Vector Model provided an effective way of relating the OI of an odor mixture with the lnOAV values of its constituents. Thus, OI of an odor mixture could be directly predicted by employing the modified Vector Model after usual quantitative analysis. Besides, it was considered that the modified Vector Model was applicable for odor mixtures which consisted of odorants with the same chemical functional groups and similar molecular structures.
منابع مشابه
The Regular Interaction Pattern among Odorants of the Same Type and Its Application in Odor Intensity Assessment
The olfactory evaluation function (e.g., odor intensity rating) of e-nose is always one of the most challenging issues in researches about odor pollution monitoring. But odor is normally produced by a set of stimuli, and odor interactions among constituents significantly influenced their mixture's odor intensity. This study investigated the odor interaction principle in odor mixtures of aldehyd...
متن کاملPerceptual interactions between characteristic notes smelled above aqueous solutions of odorant mixtures.
Twenty-two experienced panelists rated odor intensity of aqueous solutions of citral, octen-1-ol-3, and hexanal. The panel assessed unmixed components and mixtures (9 binary and 4 ternary). In sensory sessions dedicated to mixtures (n = 6), evaluation was focused on one target odor, presented at a fixed concentration. All components had lower odor intensity on mixed presentations. In many cases...
متن کاملPrediction of true critical temperature and pressure of binary hydrocarbon mixtures: A Comparison between the artificial neural networks and the support vector machine
Two main objectives have been considered in this paper: providing a good model to predict the critical temperature and pressure of binary hydrocarbon mixtures, and comparing the efficiency of the artificial neural network algorithms and the support vector regression as two commonly used soft computing methods. In order to have a fair comparison and to achieve the highest efficiency, a comprehen...
متن کاملAn Odor Interaction Model of Binary Odorant Mixtures by a Partial Differential Equation Method
A novel odor interaction model was proposed for binary mixtures of benzene and substituted benzenes by a partial differential equation (PDE) method. Based on the measurement method (tangent-intercept method) of partial molar volume, original parameters of corresponding formulas were reasonably displaced by perceptual measures. By these substitutions, it was possible to relate a mixture's odor i...
متن کاملJust noticeable differences in component concentrations modify the odor quality of a blending mixture.
The odors we perceive are mainly the result of mixtures of odorants that, however, are commonly perceived as single undivided entities; nevertheless, the processes involved remain poorly explored. It has been recently reported that perceptual blending based on configural olfactory processing can cause odorant mixtures to give rise to an emergent odor not present in the components. The present s...
متن کامل