Real-time magnetic resonance imaging of normal swallowing.
نویسندگان
چکیده
PURPOSE To evaluate the use of a novel real-time magnetic resonance imaging (MRI) technique for the assessment of normal swallowing dynamics. MATERIALS AND METHODS In a cohort of 10 healthy subjects, real-time MRI movies at 24.3 frames per second were obtained in sagittal, coronal, and axial orientation during self-controlled swallows of 5 mL pineapple juice as oral contrast bolus. All studies were performed with the use of a commercial MRI system at 3 T combining two sets of radiofrequency receiver coils. Real-time movies relied on a fast low-angle shot (FLASH) MRI sequence with radial undersampling and image reconstruction by nonlinear inversion yielding 41.23 msec acquisition time for an in-plane resolution of 1.5 mm. Evaluations focused on clinical image quality as well as visualization and temporal quantification of distinct swallowing functions. RESULTS Throughout the entire process, the swallowing dynamics were well depicted and characterized with almost no visible image artifacts in all subjects. The mid-sagittal plane turned out to be most valuable. The movies allowed for a quantitative determination of the temporal pattern of all swallowing events. CONCLUSION The proposed real-time MRI technique yields noninvasive, robust, and quantitative access to the physiology of normal swallowing in healthy subjects at high temporal resolution and image quality.
منابع مشابه
On the Physiology of Normal Swallowing as Revealed by Magnetic Resonance Imaging in Real Time
The aim of this study was to assess the physiology of normal swallowing using recent advances in real-time magnetic resonance imaging (MRI). Therefore ten young healthy subjects underwent real-time MRI and flexible endoscopic evaluations of swallowing (FEES) with thickened pineapple juice as oral contrast bolus. MRI movies were recorded in sagittal, coronal, and axial orientations during succes...
متن کاملAn investigation into the effect of magnetic resonance imaging (MRI) echo time spacing and number of echoes on the sensitivity and dose resolution of PAGATUG polymer-gel dosimeter
Background: There are various methods to read out responses of a polymer-gel dosimeter, among which the Magnetic Resonance Imaging (MRI) technique is the most common one. Optimizing imaging protocols can have significant effect on the sensitivity and the dose resolution of polymer gel dosimeters. This study has investigated the effects of the number of echoes (NOE) and the echo time spacing (ES...
متن کاملANALYTICAL STUDY OF EFFECT OF BILAYER INORGANIC AND ORGANIC COATING AROUND THE IRON OXIDE NANOPARTICLES ON MAGNETIC RESONANCE IMAGING CONTRAST
Background & Aims: In recent years, iron oxide nanoparticles have been used in contrast-enhanced magnetic resonance imaging for diagnosing a wide range of diseases. In order to provide biocompatibility and prevent the toxicity of the nanoparticles, using organic or inorganic coating around these nanoparticles is important for their application. The aim of this study is to investigate the effect...
متن کاملRepeatability of Detecting Visual Cortex Activity in Functional Magnetic Resonance Imaging
Introduction As functional magnetic resonance imaging (fMRI) is too expensive and time consuming, its frequent implementation is difficult. The aim of this study is to evaluate repeatability of detecting visual cortex activity in fMRI. Materials and Methods In this study, 15 normal volunteers (10 female, 5 male; Mean age±SD: 24.7±3.8 years) attended. Functional magnetic resonance images were ob...
متن کاملEvaluation of swallow function after tongue cancer treatment using real-time magnetic resonance imaging: a pilot study.
IMPORTANCE Magnetic resonance imaging (MRI) has the advantage of imaging swallow function at any anatomical level without changing the position of patient, which can provide detailed information than modified barium swallow, by far the gold standard of swallow evaluation. OBJECTIVE To investigate the use of real-time MRI in the evaluation of swallow function of patients with tongue cancer. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 35 6 شماره
صفحات -
تاریخ انتشار 2012