Scanning Electron Microscopic Evaluation of Residual Smear Layer Following Preparation of Curved Root Canals Using Hand Instrumentation or Two Engine-Driven Systems

نویسندگان

  • Abbasali Khademi
  • Masoud Saatchi
  • Mohammad Mehdi Shokouhi
  • Badri Baghaei
چکیده

INTRODUCTION In this experimental study, the amount of smear layer (SL) remnants in curved root canals after chemomechanical instrumentation with two engine-driven systems or hand instrumentation was evaluated. METHODS AND MATERIALS Forty-eight mesiobuccal roots of mandibular first molars with curvatures ranging between 25 and 35 degrees (according to Schneider's method) were divided into three groups (n=16) which were prepared by either the ProTaper Universal file series, Reciproc single file system or hand instrumentation. The canals were intermittently irrigated with 5.25% NaOCl and 17% (ethylenediaminetetraacetic acid) EDTA, followed by distilled water as the final rinse. The roots were split longitudinally and the apical third of the specimens were evaluated under 2500× magnification with a scanning electron microscope (SEM). The mean scores of the SL were calculated and analyzed using the non-parametric Kruskal-Wallis and Mann-Whitney U tests. RESULTS The mean scores of the SL were 2.00±0.73, 1.94±0.68 and 1.44±0.63 µm for the ProTaper Universal, Reciproc and hand instrumentation, respectively. Mean score of SL was significantly less in the hand instrumentation group than the ProTaper (P=0.027) and Reciproc (P=0.035) groups. The difference between the two engine-driven systems, however, was not significant (P=0.803). CONCLUSION The amount of smear layer in the apical third of curved root canals prepared with both engine-driven systems was similar and greater than the hand instrumentation technique. Complete cleanliness was not attained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of WaveOne and ProTaper Universal Preparation Systems in the Amount of Smear Layer/Debris Production: an in-vitro SEM Study

Background and Aim: Debris and the smear layer that remain after root canal preparations may result in failure of root canal therapies. The aim of this study was to compare the smear layer formation and the amount of residual debris following the use of WaveOne and ProTaper rotary files in mesiobuccal root canals of upper first molars by scanning electron microscopy (SEM). Materials and Method...

متن کامل

A comparative evaluation of cleaning efficacy (debris and smear layer removal) of hand and two NiTi rotary instrumentation systems (K3 and ProTaper): a SEM study.

OBJECTIVES The present study was conducted to compare the cleaning efficacy (debris and smear layer removal) of hand and two NiTi rotary instrumentation systems (K3 and ProTaper). MATERIALS AND METHODS Sixty single rooted human maxillary anterior teeth decoronated at the cementoenamel junction were used. All the specimens were divided into four groups of 15 teeth each, group I--ProTaper rotar...

متن کامل

Smear Layer Evaluation on Root Canal Preparation with Manual and Rotary Techniques using EDTA as an Irrigant: A Scanning Electron Microscopy Study.

INTRODUCTION The aim of any root canal treatment is to achieve a canal free of micro organisms, residual pulp remnants, debris and smear layer for the long term success of the procedure. Manual and automated instrumentation techniques along with proper irrigation regime is used to arrive at the aforementioned goal. Many authors focused on the preparation capabilities of various manual and rotar...

متن کامل

Evaluation of Effectiveness of Cleaning of Root Canals using Protaper and K3 Rotary Systems: A SEm Study

The aim of this in vitro study was to compare the debris and smear layer removal following root canal preparation using two different rotary systems with scanning electron microscope (SEM). The rotary systems used were Protaper and K3. Forty single rooted permanent mandibular premolars were chosen for the study. They were assigned two groups on the basis of instrumentation used. The teeth were ...

متن کامل

A comparative SEM investigation of the smear layer following preparation of root canals using nickel titanium rotary and hand instruments.

The aim of this study was to compare the efficacy of NiTi flex K-file instruments and rotary FlexMaster and Race instruments (short for reamers with Alternating Cutting Edges) in root canal preparation. A total of 75 single rooted teeth with minimum curvature (< 5 degrees ) were selected and divided into three groups, each containing 25 teeth. Canals were prepared with NiTi flex K-file, FlexMas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015