Comparison of immunoaffinity column recovery patterns of polychlorinated dibenzo-p-dioxins/polychlorinated dibenzofurans on columns generated with different monoclonal antibody clones and polyclonal antibodies
نویسندگان
چکیده
Evaluation of immunoaffinity columns (IACs) for dioxin serum sample clean-up requires a determination of the recovery of various dioxin congeners. We compared the IAC performance of different monoclonal and polyclonal anti-dioxin antibodies, measuring the recovery of congeners of polychlorinated dibenzo-p-dioxins (PCDDs). In addition, we measured the recovery of congeners of the structurally related polychlorinated dibenzofurans (PCDFs). The polyclonal antibody based IACs evaluated had lower recovery for highly chlorinated dioxin congeners, but were more specific toward 2,3,7,8-TCDD. The resemblance of the hapten to 2,3,7,8-TCDD appeared to play a clear role, but chlorines in the 2-, 3and 7-positions of the hapten were essential. Recovery of 2,3,7,8-TCDD from the IAC showed some relation to the affinity for the antibody measured by either the Ka from accelerator mass spectrometry (AMS) or with 50% inhibition of color activity (IC50) determined from an ELISA analysis. The IACs prepared from four monoclonal antibodies (Mabs) derived from a common hapten showed differences in their retention patterns of PCDDs/PCDFs. Comparison of IC50 from ELISA with recovery from the IACs indicated that a minimum IC50 of 100 ppb was required for satisfactory recovery from the IAC, but the correlation was poor, indicating other factors were involved. Mab DD3 showed the broadest spectrum of the Mabs and showed satisfactory recoveries of all of the dioxin congeners, except OCDD. In addition, DD3 showed good recovery toward 2,3,4,8-TCDF, 2,3,4,7,8-PeCDF and 2,3,4,6,7,8-HxCDF but has poor recovery when PCDFs have a chlorine substitution in the 1-position. © 2002 Elsevier Science B.V. All rights reserved.
منابع مشابه
Establishing an alternative method for the quantitative analysis of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans by comprehensive two dimensional gas chromatography-time-of-flight mass spectrometry for developing countries.
Comprehensive Gas Chromatography-Time-of-Flight Mass Spectrometry (GC×GC-TOFMS) methodology has been refined for the analysis of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in samples with different matrices. This is specifically for application in developing countries where access to gas chromatography-high resolution mass spectrometry (GC-HRMS) and high...
متن کاملSeparation of 2378 Tcdd, 2378 Tcdf, 23478 Pecdf, and Other 2378 Pcdds and Pcdfs on a New High-temperature Gc Column
Introduction EPA Methods 1613 (Tetrathrough Octa-Chlorinated Dioxins and Furans by Isotope Dilution HRGC/HRMS) and 8290a [Polychlorinated Dibenzodioxins(PCDDs) and Polychlorinated Dibenzofurans (PCDFs) By High Resolution Gas Chromatography/High Resolution Mass Spectrometry (HRGC/HRMS)] specify the use of a 60m 5% diphenyl 95% dimethyl polysiloxane GC column (e.g. DB-5, Rxi-5ms) for 2378 TCDD is...
متن کاملPOLYCHLORINATED DIBENZO-p-DIOXINS AND DIBENZOFURANS AS PRODUCTS OF PHOTODEGRADATION OF CHLOROPHENOLS
Results of the study into photodegradation of 2,4,6-trichlorophenol and pentachlorophenol in aqueous solutions have been presented. Quantum yields and rate constants of the reactions were determined. Intermediate products were identified by GC/MS method. The experiments confirmed formation of polychlorinated dibenzo-p-dioxins and dibenzofurans in photochemical reactions. The findings showed tha...
متن کاملAn improved clean-up strategy for simultaneous analysis of polychlorinated dibenzo-p-dioxins (PCDD), polychlorinated dibenzofurans (PCDF), and polychlorinated biphenyls (PCB) in fatty food samples.
The study and extension of a simple automated clean-up method for polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) to a broad range of polychlorinated biphenyls (PCB) is described. The isolation of seven PCDD, ten PCDF, and three coplanar PCB (cPCB) is extended to eight monoortho substituted PCB and seven so-called "marker PCB" (Aroclor 1260) for fatty food samp...
متن کاملPolychlorinated dibenzo-p-dioxins and dibenzofurans in fly ash and cinders collected from several municipal incinerators in Japan.
Determination of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) in fly ash and cinders collected from nine municipal incinerators in Japan was made. The concentrations of PCDDs and PCDFs in this study were generally in the same range as those in Europe and North America. However, the rather different congener composition compared with those published already...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002