ECG Monitoring Garment Using Conductive Carbon Paste for Reduced Motion Artifacts

نویسندگان

  • Jin-Woo Lee
  • Kwang-Seok Yun
چکیده

The heart is a fundamental organ of the human circulatory system and the continuous measurement of electrocardiogram (ECG) signals is of great importance for pre-detection of heart diseases. Dry electrodes that do not require electrolyte gel have been developed for wearable ECG monitoring applications. However, this kind of electrode often introduces motion artifacts because of the high contact impedance between the electrode and skin. We propose a wearable ECG monitoring garment that employs electrodes made of conductive carbon-based paste. This paste is directly applied to the skin and after drying for 5 min, it forms a patch electrode that is detachable and flexible. The contact impedance between the patch electrode and the skin is very low because the paste covers the skin in a conformal manner. The experimental results show that the contact area of the carbon-based paste on the skin replica is almost 100%. At frequencies under 10 Hz, the contact impedance of the patch electrode is of 70.0 kΩ, much lower than the typical 118.7 kΩ impedance of a Ag/AgCl electrode. We also demonstrate that the ECG signals measured using the custom-designed garment and the patch electrodes are very stable even during actions such as walking and running.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel dry electrodes for ECG monitoring.

The development, fabrication and characterization of two novel dry bioelectrodes--conductive and capacitive ones--for biopotential monitoring are presented. The new electrodes have the potential to improve the applicability of dry electrodes in ambulant recording of ECG by reducing motion artifacts as well as the contact impedance to the skin. Furthermore, a passive filter network is integrated...

متن کامل

Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory Electrocardiograms

This study proposes the use of flexible capacitive electrodes for reducing motion artifacts in a wearable electrocardiogram (ECG) device. The capacitive electrodes have conductive foam on their surface, a shield, an optimal input bias resistor, and guarding feedback. The electrodes are integrated in a chest belt, and the acquired signals are transmitted wirelessly for ambulatory heart rate moni...

متن کامل

Utility of Electrocardiography (ECG)-Gated Computed Tomography (CT) for Preoperative Evaluations of Thymic Epithelial Tumors

BACKGROUND Preoperative evaluation of invasion to the adjacent organs is important for the thymic epithelial tumors on CT. The purpose of our study was to evaluate the utility of electrocardiography (ECG)-gated CT for assessing thymic epithelial tumors with regard to the motion artifacts produced and the preoperative diagnostic accuracy of the technique. MATERIAL/METHODS Forty thymic epitheli...

متن کامل

Signal Processing of ECG Using Matlab

The ECG signal, even rest ECG, is often corrupted by artifacts produced by varies sources of either artificial or biological nature. Main artificial artifacts are power line interference, Impulse noise, Electrostatic potentials and noise of electronic devices. The main biological artifacts are motion artifacts and muscle artifacts (EMG signal) The present work introduces the digital filtering m...

متن کامل

Reduction of Motion Artifacts and Improvement of R Peak Detecting Accuracy Using Adjacent Non-Intrusive ECG Sensors

Non-intrusive electrocardiogram (ECG) monitoring has many advantages: easy to measure and apply in daily life. However, motion noise in the measured signal is the major problem of non-intrusive measurement. This paper proposes a method to reduce the noise and to detect the R peaks of ECG in a stable manner in a sitting arrangement using non-intrusive sensors. The method utilizes two capacitive ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017