Long-term outcomes after St. Jude Medical mechanical valve implantation.
نویسندگان
چکیده
patient-year), major bleeding events (1.0%/patient-year), and aortic valve reoperation (0.26%/patient-year). They also reported that valve-related death was the most common cause of death (26.8%) and that the rates of freedom from valve-related death were 96.2%, 92.7%, 88.8%, and 86.6% at 5, 10, 15, and 20 years, respectively. These results compare favorably with the findings of previous reports,1–4 and were mainly affected by control of the prothrombin-international normalized ratio (PTINR). In the Japanese guidelines, the optimal range for PTINR during aortic mechanical valve replacement is 2.0–2.5 (vs. 2.0–3.0 for mitral mechanical valves and atrial fibrillation [AF]).8 Although the PT-INR target was the same as in the Japanese guidelines, the frequency of PT-INR control within the optimal range was not ascertained in this study. Unfortunately, PT-INR tends to drift, which can lead to thromboembolic and bleeding events. Furthermore, for very long periods of warfarin administration, it may be important to quantify the maintenance of the target PT-INR (eg, the time in the therapeutic range for PT-INR, which has been used for AF).9,10 Moreover, the risk of thromboembolic and bleeding events varies according to age, and it is possible that the specific optimal range for PT-INR might vary according to the patient’s age. One complication of mechanical valve use is pannus formation during the follow-up.11 Although many factors are involved (eg, inflammation, thrombus formation, and turbulence around the valve), the precise cause of pannus formation has not been determined.12 Therefore, given that reoperations are rarely performed for mechanical valves, the frequency of pannus formation is very important. In this context, the SJM mechanical he St. Jude Medical (SJM) mechanical valve is a bileaflet valve that is constructed using pyloric carbon to achieve the concept of “one valve in one life.” Since its development in 1977, the SJM valve has become the most used mechanical valve in Japan and throughout the world. Because of its excellent durability, the SJM valve is typically used for relatively young patients,1 and its high performance and low event rate during long follow-ups have been reported previously (Table).1–4 The long-term outcomes are of specific interest, and cardiac surgeons are especially interested in the rates of thromboembolism, bleeding, reoperation, valve-related deaths, and valve-related complications (pannus formation, paravalvular leakage with hemolysis, valve thrombosis, and prosthetic valve endocarditis). According to the Society of Thoracic Surgeons/American Association for Thoracic Surgery (STS/AATS) guidelines for reporting mortality and morbidity after cardiac valve interventions,5,6 these complications should be evaluated using standardized valve-specific criteria. In particular, thromboembolism and bleeding, which have rates of development that are constant over time, should be evaluated by not only the actual rates but also the linearized rates.
منابع مشابه
Unusual Disc Dislodgement of a Björk-Shiley Valve after Long-term Implantation
https://e-kcj.org A 40-year-old male was admitted to the cardiac care unit (CCU) due to severe pneumonia associated with unstable hemodynamics. Meanwhile, a grade 3–4 systolic murmur was heard at the left lower sternal border. Tracing his history back, he had undergone mitral valve replacement with a Björk-Shiley convexoconcave prosthetic valve (single tilting disc mechanical valve) 25 years be...
متن کاملReplacement of the aortic valve in patients under 50 years of age: long-term follow-up of the St. Jude Medical prosthesis.
BACKGROUND Aortic valve replacement in the young adult (aged 18 to 50 years) is a choice between a mechanical prosthesis with attendant lifelong anticoagulation or biological prostheses of varying types that may have limited life expectancy in this age group. METHODS The Cardiac Surgical Research Foundation database was accessed to determine long-term outcomes in patients having aortic valve ...
متن کاملEnlargement of mitral valve ring in a young woman with severe prosthesis-patient mismatch.
Mechanical prosthesis is the first choice for valve replacement at the mitral position in children. Replacement of the original prosthesis because of prosthesis-patient mismatch (PPM) is almost inevitable when prostheses are implanted in small children. The impact of PPM on long-term mortality becomes significant when the effective orifice area (EOA) is severely reduced. In these cases prosthes...
متن کاملImpact of prosthesis-patient mismatch on long-term survival in patients with small St Jude Medical mechanical prostheses in the aortic position.
BACKGROUND The impact of aortic prosthesis-patient mismatch (P-PtM) on long-term survival is unclear. METHODS AND RESULTS Between 1985 and 2000, 388 patients at Mayo Clinic in Rochester, Minn, underwent aortic valve replacement (AVR) with 19- or 21-mm St Jude Medical prostheses and had transthoracic echocardiography within 1 year after AVR. Mean age of patients was 62+/-13 years; 69% were fem...
متن کاملPortico Transcatheter Implantation in a Patient with Mechanical Mitral Valve
Transcatheter aortic valves implantation (TAVI) is a valid treatment for high-risk surgical candidates with symptomatic severe aortic stenosis; the safety and effectiveness of TAVI have been demonstrated in numerous clinical studies, national registries and randomized trials. Nevertheless, from this cohort of patients have been often excluded patients with prior mitral valve surgery because con...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation journal : official journal of the Japanese Circulation Society
دوره 79 11 شماره
صفحات -
تاریخ انتشار 2015