Acid-Soluble Internal Capsules for Closed-Face Cassette Elemental Sampling and Analysis of Workplace Air

نویسندگان

  • Martin Harper
  • Kevin Ashley
چکیده

Airborne particles that are collected using closed-face filter cassettes (CFCs), which are used widely in the sampling of workplace aerosols, can deposit in places other than on the filter and thereby may not be included in the ensuing analysis. A technique for ensuring that internal non-filter deposits are included in the analysis is to collect airborne particles within an acid-soluble internal capsule that, following sampling, can be dissolved along with the filter for subsequent elemental analysis. An interlaboratory study (ILS) was carried out to evaluate the use of cellulosic CFC capsule inserts for their suitability in the determination of trace elements in airborne samples. The ILS was performed in accordance with an applicable ASTM International standard practice, ASTM E691, which describes statistical procedures for investigating interlaboratory precision. Performance evaluation materials consisted of prototype cellulose acetate capsules attached to mixed-cellulose ester filters. Batches of capsules were dosed with Pb-containing materials (standard aqueous solutions, and certified reference material soil and paint). Also, aerosol samples containing nine target analyte elements (As, Cd, Co, Cr, Cu, Fe, Pb, Mn, and Ni) were generated using a multiport sampler; various concentrations and sampling times were employed to yield samples fortified at desired loading levels. Triplicates of spiked capsules at three different loadings were conveyed to each volunteer laboratory; loading levels were unknown to the participants. The laboratories were asked to prepare the samples by acid dissolution and to analyze aliquots of extracted samples by atomic spectrometry in accordance with applicable ASTM International Standards. Participants were asked to report their results in units of μg of each target element per sample. For the elements investigated, inter-laboratory precision and recovery estimates from the participating laboratories demonstrated the utility of the cellulosic capsule inserts for the measurement of sampled trace elements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laboratory study of selected personal inhalable aerosol samplers.

Assessment of inhalable dust exposure requires reliable sampling methods in order to measure airborne inhalable particles' concentrations. Many inhalable aerosol samplers can be used but their performances widely vary and remain unknown in some cases. The sampling performance of inhalable samplers is strongly dependent on particle size and ambient air velocity. Five inhalable aerosol samplers h...

متن کامل

Evaluation of organic carbon, elemental carbon, and water soluble organic carbon concentration in PM2.5 in the ambient air of Sina Hospital district, Tehran, Iran

In the present study, carbon species including organic carbon (OC), elemental carbon (EC), and water-soluble organic carbon (WSOC) concentration in PM2.5 were assessed at an urban site of Tehran, Iran during March to June 2014. The PM2.5 samples were collected using an frmOMNITM Ambient Air Sampler. Thermal gravimetric analysis (TGA) was used to analyze OC and EC. The results showed that PM2.5 ...

متن کامل

Evaluation of Parameters Influencing Hexavalent Chromium Mist Sampling: A Full Factorial Design

A chromium electroplating bath with the ability to produce homogenous mist was used to evaluate parameters influencing hexavalent chromium (Cr+6) mist sampling methods. The results of 48 Cr+6mist samples collected using the U.S. National Institute for Occupational Safety and Health method 7600...

متن کامل

بررسی مقایسه ای عوامل مؤثر بر تعیین تراکم کروم شش ظرفیتی بعنوان یک سرطانزای شغلی

Introduction & Objective: Hexavalent chromium, Cr+6, is a very harmful pollutant and a relatively unstable compound that is present in many industries. It is a known human respiratory carcinogen and occupational exposure to this chemical is associated with different health hazards. The purpose of this study was to evaluate the effects of four parameters including: type of sampling head, sampl...

متن کامل

The Development and Validation of a Diffusive Sample with a Variable Sampling Rate for Long‐term Sampling of VOCs

PS 403‐17 Sampling and Analysis of Airborne Trichloramine in Indoor Swimming Pools T. Chu, S. Tsai, National Taiwan University, Taipei, Taiwan; S. Cheng, Council of Labor Affairs, Executive Yuan, Taipei, Taiwan. Objective: In swimming pools, visitors can contribute various kinds of organic nitrogen, such as sweat, or skin particles, which would react with chlorine to form trichloramine. It has...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2013